Industio
CI-134 Series User’s Manual
2-1
2
2
2
Hardware Installation
The
installation of the
Industio
CI-134 Series consists of hardware and software
installation. The hardware installation is detailed in this chapter. The next chapter
deals with the software installation for various operating systems.
First Thing to Do: Interface Settings
1.
Before installing the board into the slot, you should set all the jumpers and
switches to what you want.
The default (factor y) settings ar e set to RS-485,
Auto Data Dir ection Contr ol mode, indicated as *
.
l
CAP Jumper JP1:
Open *
Not forcing the CAP address to 0xA700.
Shor t
Force the CAP address to 0xA700.
Set to this if you want to do
quick har dwar e installation.
Or forget the CAP address when
you want to re-configure the board with IO-IRQ.
Termination Resistor Jumper for Port 1
Industio
CI-134 Series Board
Data Mode Switch
ON
ON
1 2 3 4
CAP Jumper
JP1
ON
JP3
JP4
JP6
JP5
Interface Switch
Termination Resistor Jumper for Port 2
Termination Resistor Jumper for Port 4
Termination Resistor Jumper for Port 3
1 2 3 4