Industio
CI-132 Series User’s Manual
configuration program will automatically update the hardware settings of the board
while updating the software settings. This saves the trouble doing hardware
configuration. However, remember to
cold start the system every time the
configuration changed
.
Hardware Installation with IO-IRQ Utility
This section is for users in the following cases, who can not use quick hardware
installation:
u
Install two or more
Industio
CI-132 Series boards in a system.
u
Fail to install, due to the I/O address 0xA700 is not available or has conflict in
the system.
u
Use operating systems other than Windows NT and 95/98.
Before proceeding to the
software
(
driver
)
installation
, detailed in the next chapter,
“Software Installation”, do
hardware configuration
to setup the I/O and IRQ with
“Io-irq.exe”
, detailed in the next section.
Remember to keep the hardware settings in mind for the software installation.
The
Industio
CI-132 Series has the following default (factory) settings:
I/O address :
0x180
(1st port),
0x188
(2nd port)
IRQ :
10
INT Vector :
0x1C0
Because the ASIC-designed
Industio
CI-132 Series has no switch and no jumper for
configuring manually the I/O address, IRQ, INT Vector, etc. of the boards, you
must
run the software utility,
Io-irq.exe
, in the driver diskette under
DOS
system to
change the hardware configuration.
1.
Choose a PC that has
DOS
system inside.
2.
Power off the PC.
3.
Make sure no hardware conflict and plug the board in a free 16-bit slot of the PC,
one board at a time with JP1 open
.