CAN Interface Board User’s Manual
CAN Interface Board Utility
Transmit Message
The function sends a CAN message with or without the block operation. The default setting is
Extended Frame
.
Parameter Options
Description
ID (Hex)
Standard Frame:
0-0x7FF
Extended Frame: 0-0x1FFFFFFF
Set the specified ID of frame
to be transmitted.
Length
0-8
Data length code of a frame.
Data (Hex)
0-0xFF
Data byte.
Parameter
Check Description
Standard Frame
Empty
11-bit ID CAN frame
Extended Frame
Checked
29-bit ID CAN frame(Default setting)
Remote Request
Checked
Set the frame as remote request frame to be
transmitted.
Select this option to ignore the data field.
Self Reception Request
Checked
Select this option to allow the frame to be received
by the controller who transmits the frame.
ATTENTION
The Standard Frame parameter does not display on the panel. If you need to select Standard
Frame, remove the checkmarks from the other three check boxes.