Firmware Recovery
When the LEDs of
FAULT
,
Signal Strength
,
CLIENT
,
BRIDGE
and
WLAN
all light up
simultaneously and blink at one-second interval, it means the system booting has failed. It may
result from some wrong operation or uncontrollable issues, such as an unexpected shutdown
during firmware update. The AWK-4121 is designed to help administrators recover such damage
and resume system operation rapidly. You can refer to the following instructions to recover the
firmware:
Connect to the AWK-4121’s ES-232 console with
115200bps and N-8-1
. You will see the
following message shown on the terminal emulator every one second.
Press
Ctrl - C
and the following message will appear.
Enter
2
to change the network setting. Specify where the AWK-4121’s firmware file on the TFTP
server and press
y
to write the settings into flash memory.
AWK-4121 restarts, and the “Press Ctrl-C to enter Firmware Recovery Process…” message will
reappear. Press
Ctrl-C
to enter the menu and select
1
to start the firmware upgrade process.