- 14 -
Installation
DIN-rail mounting (standard),
wall mounting (optional)
Environmental Limits
Operating
Temperature
Standard Models: 0 to 60°C (32 to 140°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)
Storage Temperature -40 to 85°C (-40 to 185°F)
Ambient Relative
Humidity
5% to 95% (non-condensing)
Power Requirements
Input Voltage
9 to 30 VDC
Input Current
1.3A@9VDC, 0.39A@30VDC, 0.49A@24VDC
Connector
3-pin removable terminal block, 500 V insulation
Power Consumption 11.7 W
Reverse Polarity
Protection
Present
Standards and Certifications
Safety
UL 60950-1, EN 60950-1
EMC
EN 61000-6-2/61000-6-4, EN 55032/55024
EMI
CISPR 22, FCC Part 15B Class B
EMS
IEC 61000-4-2 ESD: Contact 8 kV; Air 15 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
IEC 61000-4-4 EFT: Power 2 kV; Signal 1 kV
IEC 61000-4-5 Surge: Power 2 kV; Signal 1 kV
IEC 61000-4-6 CS: 10 V
IEC 61000-4-8
Radio
EN 301 489-1/17, EN 300 328, EN 301 893, MIC,
FCC ID SLE-1137C, WPC, ANATEL, KC, RCM,
SRRC
Note: Check Moxa’s website for the most up-to-date certification status.
Reliability
MTBF
1,125,942 hrs
Warranty
Warranty Period
5 years
Details
See www.moxa.com/support/warranty.aspx
ATTENTION
•
The AWK-1137C is
NOT
a portable mobile device and should
be located at least 20 cm away from the human body.
•
The AWK-1137C is
NOT
designed for the general public. A
well-trained technician is required to deploy AWK-1137Cs
and safely establish a wireless network.
ATTENTION
Use the antennas correctly: The 2.4 GHz antennas are needed
when the AWK-1137C operates in IEEE 802.11b/g/n. The 5 GHz
antennas are needed for operation in IEEE802.11a/n. Make sure
that the antennas are installed in a safe area, which is covered by
a lightning protection or surge arrest system.