Introduction 

 
Thank you for purchasing a Movacolor metering device. This manual is addressed to operators and 

qualified

 

technicians

 taking care of the metering of dry additives to ensure correct use of the Movacolor 

dosing unit.  

 IMPORTANT NOTE: THIS MANUAL MUST BE READ BEFORE INSTALLING THE DOSING UNIT. KEEP THIS 

MANUAL IN A PLACE ACCESSIBLE FOR ALL OPERATORS. 

 

 

Symbols 

 
   

 Important note 

Attention; safety regulations for the operator 

 

 

Terms 

 

Operator:

  

A person charged to operate, adjust, maintain and clean the machine. 

 

Qualified

 

Technician:

  

A specialized, suitable trained person authorized to execute the installation, 
non-routine maintenance, or repairs requiring special knowledge of the 
machine and how it operates. 

Multi component:

 

Two or more dosing systems on one machine. 

 
 

 

Transport 

 
To protect the Movacolor unit against damage during transport, the unit is packed in a cardboard box filled 
with polyurethane foam. Delivery terms are Ex-Works Sneek, The Netherlands. Buyer is responsible for the 
transport. Movacolor cannot be held liable for any damage during transport. 

 

 

Receipt 

 
Check the unit thoroughly upon receipt. Pass any remarks to the local agent or Movacolor within 8 days 
upon receipt of goods.  

Summary of Contents for MCTC CPU Exchange

Page 1: ...MCTC CPU Exchange Software version MCTC2 X and higher Manual revision 03 Language English Date March 2017 ...

Page 2: ...change manual Index Index 2 1 Introduction 3 Symbols 3 Terms 3 Transport 3 Receipt 3 2 General information 4 Safety 4 Certification 4 Operating environmental conditions 4 3 CPU Exchange 5 4 Touchscreen calibration 7 ...

Page 3: ...aintain and clean the machine Qualified Technician A specialized suitable trained person authorized to execute the installation non routine maintenance or repairs requiring special knowledge of the machine and how it operates Multi component Two or more dosing systems on one machine Transport To protect the Movacolor unit against damage during transport the unit is packed in a cardboard box filled...

Page 4: ...C Always switch off the Movacolor control cabinet and disconnect the mains power plug from electrical power before performing maintenance Dangerous voltages are present inside the control cabinet for up to 2 minutes after it has been switched off Certification The Movacolor dosing unit is designed and produced in conformity with the following European regulations 1 standards for machinery health s...

Page 5: ...e mains power is unplugged MCTC CPU EXCHANGE Open the MCTC control cabinet by loosening the 4 screws on the both sides of the control cabinet Loosen the 2 upper screws remove the 2 lower screws Unlock the CPU board by moving both the locks sideward simultaneously gently The CPU board pops up a little bit you can take it out of the socket now ...

Page 6: ...ection side first in the socket the board within a small angle related to the mainboard Push down the board gently until it clicks in the locking mechanism Be sure the module is inserted correctly straight WRONG CORRECT Close the MCTC control cabinet and place tighten the 4 screws ...

Page 7: ...gin required Copy the file mctc_ts calibrate muf to an empty USB memory stick only one file with filename starting with mctc should be located on the USB memory stick Power down the MCTC controller main switch off Insert the USB memory stick in the MCTC controller Power up the MCTC controller main switch on Follow the instruction on the screen You need to press the cross marks shown on the display...

Reviews: