25/29
NT 1004-H00 10 16 SLS24 i - SLS36 i e
• Drain the transmission following the board below :
• Data with
MOUVEX Standard oil CS05* :
• Data with
MOUVEX Silicone free oil CS23* :
• Data with
other customer oil
: the drawing interval is
defined by the customer (tests results) regarding the oil
specifications and the pump conditions.
• Drain the pump by removing the drain plug with its
seal
773-774
and the breather
715
.
• Replace the drain plug and its seal.
• Fill the transmission with 4,5 litres of oil*.
• Check oil level that the level is between 1 and 5 mm above
the shaft.
• Screw back the breather
715
.
Oil level
Min : 1 mm
Max : 5 mm
Temperature of product
pumped / heating product
Draining interval
(running hours)
80 °C < T ≤100 °C
12 000
T ≤ 80 °C
24 000
CAUTION
THE SURFACES OF THE PUMP AND
OIL TRANSMISSION CAN BE AT A
TEMPERATURE LIABLE TO CAUSE
INJURY OR SEVERE DAMAGE.
Excessive temperature-
can cause injury
or severe damage.
CAUTION
THE PUMP LUBRICANT IS VERY SLIPPERY
AND MAY CAUSE SERIOUS INJURY. ANY
SPILLS MUST BE CLEANED UP.
Slippery lubricant.
Spills should be
cleaned up.
Temperature product
pumped / heating product
Draining interval
(running hours)
T < 100 °C
5 000
11. DRAINING OF BEARING
12. OPTIONS
12.1 Bellows monitoring system
See Instructions 1011-S00.
* Standard oils provided by MOUVEX
(Safety data sheet is supplied
on inquiery) :
CS05 Food synthetic oil
CS23 Silicone free oil for transmission
* Other oil provided by customer.