background image

Page 20

A c c e s s o r i e s

Model

Item #

Universal Charger (for EZ-TorQ)

770301

Case (for EZ-TorQ)

600729

Battery Pack (for EZ-TorQ)

603107

Brush Cap

14-501830

RS232 Cable

773064

Serial to USB Adapter

773069

1/4 F/Hex Sq. Dr Adapter (17mm F/Hex)

600727

Square Dr. Adapter (1/4 Sq. Dr x 1/4 Hex x 2" Oal)

120143

Spring RDA10i

070600

Spring RDA50i

070605

Spring RDA100i

070610

Spring RDA150i

070615

Service

Mountz Inc. features an experienced calibration and repair staff. Our trained technicians can calibrate and repair most
any tool. Mountz provides rapid service with quality that you can trust as we offer two state-of-the-art calibration lab and
repair facilities that can calibrate up to 20,000 lbf.ft. 

Since 1965, Mountz Inc. has proven its in-depth knowledge of torque and torque solutions by consistently developing,
producing, marketing and servicing highly sophisticated, cutting-edge tools. Mountz Inc. is known to the industry as the
premier torque tool supplier. 

Tool Service & Repair Capability

Torque Wrenches: Click, Dial, Beam, Cam-Over & Break-Over

Torque Screwdrivers: Dial, Micrometer, Preset & Adjustable

Torque Analyzers/Sensors: All brands

Electric Screwdrivers: All brands

Air Tools: All brands

Impact Wrenches, Drills, Pulse Tools, Grinders, Percussive Tools, 

Air Screwdrivers, Nutrunners, DC Controlled Nutrunners

Torque Multipliers: All brands

Corporate Headquarters: 

1080 North 11th Street, San Jose, CA 95112    Phone: (408) 292-2214   Fax: (408) 292-2733

www.mountztorque.com

Mountz Service Locations

Eastern Service Center

19051 Underwood Rd.

Foley, AL 36535

Phone: (251) 943-4125

Fax: (251) 943-4979

Western Service Center

1080 N.11th Street

San Jose, CA 95112

Phone: (408) 292-2214

Fax: (408) 292-2733

www.mountztorque.com

[email protected]

Summary of Contents for EZ-TorQ II

Page 1: ...Corporate Headquarters 1080 North 11th Street San Jose CA 95112 Phone 408 292 2214 Fax 408 292 2733 www mountztorque com Operating Instructions Version 3 2 3 22 2017 ...

Page 2: ...to conduct Quick Tool Tests Data Logging and Sensor Calibration Flash memory allows upgrades to be done by the user in the field internet through the RS 232 port Easy to use Menu Structure Six digit display Ability to download readings to PC via RS 232 or via USB Real time out via RS 232 High Capacity Li Ion Batteries for long life The unit will store a total of up to 150 data points Real time gra...

Page 3: ...m N m cN m Track Peak Backlight Clear Memory Auto Clear Tolerance Direction Contrast Language Sub Menu Sub Menu Sub Menu Enter Enter Sleep Mode Enter Filter Pan Pac 130 Hz Mountz 170 Hz Sub Menu Enter Data Output ISO 500 Hz First Peak Corporate Headquarters 1080 North 11th Street San Jose CA 95112 Phone 408 292 2214 Fax 408 292 2733 www mountztorque com ...

Page 4: ...mmend securing the torque tester to a work bench before operating Immobilizing the analyzer is critical for the safety of the operator as well as for the accuracy of torque measurements during operation Mounting the unit to a fixed surface offers the most secure way to immobilize the analyzer and is recommended when used at a permanent location It employs two spring loaded mounting screws from the...

Page 5: ...hanged during a Quick Test operation 1 Press Menu button 2 With the Quick Test selected press Enter key Selecting Quick Test Once the Quick test is started the Menu indication at the bottom left of the EZ TorQ screen will change to Stop When the desired number of readings are collected press the Menu key to end the Quick test Quick Test Units Mode Setup Filter Quick Test Units Mode Setup Filter Co...

Page 6: ... Setting 4 The Main or reading screen will display the value of the selected Mode Selecting Mode Options Backlight First Peak Data Output Clear Memory Auto Clear Tolerance Direction 1 Select Setup by highlighting and pressing Enter 2 Use the Scroll Up or Down key to toggle through the Setup options 3 Press Enter key to select a Setup Setting Selecting Setup Page 6 Note Contrast Language Sleep Mode...

Page 7: ... L AY The first function is used to clear any torque reading on the display When the ENTER key is pressed it also sends the displayed reading to the RS 232 port for printing or downloading to an application program After sending the data the readings will automatically be cleared from the display VA L I D AT I N G S E T U P S The other function is the validation of user selection during set ups se...

Page 8: ...peak is detected the display will show the torque value If a second peak is detected then it will be displayed in the lower right in small reverse video The function of this mode is primarily used for testing and calibrating click type mechanical torque wrenches The tester captures the point where the wrench first clicks As additional force is applied a secondary torque is displayed This mode may ...

Page 9: ...Clear is selected the torque values during operation will indefinitely be display until the user presses the Enter key The Auto Clear timer can be set from 1 to 5 seconds If a Quick Test is in operation the readings will be stored when the Auto Clear timer expires or the user presses Enter if in Manual Clear mode Use the Up Down scroll keys to change between Manual and Auto and press Scroll Left t...

Page 10: ... keys to change between sleep mode On Off When finished press Enter to end the process and store the setting Caution The meter will have significantly less operational life if Sleep Mode is turned off Sleep SLEEP MODE SETTING Auto Sleep On TOLERANCE SETTING Low 10 000 High 14 00 Units Lbf in The Tolerance parameters control the Go and No Go multicolored Green Red LED and In Tolerance and Out of To...

Page 11: ...uency setting the operator will see limited or no change to the torque values being dis played as the speed of a power tool is increased The 170Hz frequency filter in conjunction with software averaging cuts off signals above 170Hz which will result in little or no change to torque values being displayed with increased RPM 3 ISO 500Hz At this frequency setting the operator will see an increase in ...

Page 12: ... and irregular peaks that cause poor repeatability Each RDA has an effective torque range and will supply repeatable torque data within that range if used correctly Always use a quality joint rate simulator run down adapter when testing power tools in a simulated application Use the peak mode The Peak mode is designed to meet the demanding frequency requirements for testing dynamic torque applicat...

Page 13: ...ator to conduct Tool Tests Data logging and Sensor Calibration 1 Insert the CD into the PC and the EZ TorQ II Interface Program splash screen will appear Click on the Install EZ TorQ II Program Page 13 Corporate Headquarters 1080 North 11th Street San Jose CA 95112 Phone 408 292 2214 Fax 408 292 2733 www mountztorque com ...

Page 14: ... Program turn on the unit and connect it to a PC through the RS 232 port 6 A Green light will show on the Interface Program indicating that the software was installed and the unit is connected properly Corporate Headquarters 1080 North 11th Street San Jose CA 95112 Phone 408 292 2214 Fax 408 292 2733 www mountztorque com ...

Page 15: ...through the com port selections and click ok on the available selections until the On Line indicator turns Green The EZ TorQ meter must be turned on to establish a connection The COM port set ting can also be verified by checking port assignments via device manager C O M P o r t S e l e c t i o n Corporate Headquarters 1080 North 11th Street San Jose CA 95112 Phone 408 292 2214 Fax 408 292 2733 ww...

Page 16: ... chance to add further notes to the test at this point The results will save in the PC in a location of your choice in a folder under the name entered in the Operator field in the upper portion of EZ TorQ Meter Interface software The results are stored in a csv file which can be opened in Excel or using a text editor program such as Notepad The file name will be the QuickTest number followed by th...

Page 17: ...rque vs time graph can be accessed by clicking on the Data logging tab and then clicking on the Start button on the top left side of the screen After torque has been applied and the desired graph has been obtained click the Stop button to stop the collection of readings There are different features available at the top of the Start button that can be utilized for the graph Corporate Headquarters 1...

Page 18: ...e program does when CD is inserted into the PC Insert the CD into the PC Locate the Bootloader exe file and click on it a small window will pop up as shown below The EZ TorQ II is supplied with RS 232 cable adapter and USB serial converter adapter Connect the RS 232 cable to the torque tester and the computer Turn on the EZ TorQ II unit Click the button Start boot loader on device and the EZ TorQ ...

Page 19: ...ader window as the process takes place In some cases when a computer does not have an RS 232 connector and the USB serial converter adapter is used the serial port where the connection is received might come in at a port different than COM1 In this situation if the user wants to update the firmware through the Bootloader program the user needs to perform the following procedure 1 Right Click the B...

Page 20: ...torque and torque solutions by consistently developing producing marketing and servicing highly sophisticated cutting edge tools Mountz Inc is known to the industry as the premier torque tool supplier Tool Service Repair Capability Torque Wrenches Click Dial Beam Cam Over Break Over Torque Screwdrivers Dial Micrometer Preset Adjustable Torque Analyzers Sensors All brands Electric Screwdrivers All ...

Reviews: