Continuation „Analog Menu”:
ANALOG GAIN (%)
This parameter specifies the maximum conversion of the analog output in %.
e. g. 102.00 corresponds to a conversion of 10.2 V or 20.4 mA, when the ANALOG END value is reached.
e. g. 95.00 corresponds to a conversion of 9.5 V or 18 mA, when the ANALOG END value is reached.
0
Smallest gain
100
Default value
110
Highest gain
ANALOG OFFSET (%)
This parameter sets the zero offset of the output.
e.g. 0.20 result in an offset of 0.02 V or 0.04 mA at ANALOG START value
-99,99
Smallest zero offset
0
Default value
+99,00
Highest zero offset