Speed A Settings
In this menu, the settings for a frequency measurement / tachometer on channel A are defined.
Depending on the operating mode selected, only input A or input A and input B with 90 ° phase offset are
active for forward / reverse direction detection.
DISPLAY VALUE
Desired value, which should be displayed at the setting of BASE FREQUENCY.
1
Smallest value
1000
Default value
99999999
Highest value
BASE FREQUENCY (HZ)
Reference frequency for the desired DISPLAY VALUE.
1
Smallest value
100
Default value
500000
Highest value
DECIMAL POINT
This value defines the position of the decimal point.
0 NO
No decimal point
1 0000000.0
Decimal point at the specified position
2 000000.00
Decimal point at the specified position
3 00000.000
Decimal point at the specified position
4 0000.0000
Decimal point at the specified position
5 000.00000
Decimal point at the specified position
6 00.000000
Decimal point at the specified position
7 0.0000000
Decimal point at the specified position
SAMPLING TIME (S)
The configured value corresponds to the minimum measurement time. The Parameter is used as a filter in case
of irregular frequencies. This parameter directly affects the response time of the unit.
0.005
Shortest Sampling time
0.1
Default value
9.999
Longest Sampling time