background image

Pu21003b_oi_e.doc / Apr-16 

Page 1 / 11 

Operation Manual 

PU 210 

Level Converter, Potential Separator and Direction 

Signal Decoder for Incremental Encoder Signals 

Signal inputs A, B, Z and /A, /B, /Z, adjustable to either RS422
format or TTL level or HTL (10-30V) level

Signal outputs A, B, Z and /A, /B, /Z, likewise adjustable to either
RS422 format or TTL level or HTL (10-30V) level

Potential separation between input and output

Conversion of a A/B quadrature direction signal to a static direction
output and vice-versa

Encoder connection alternatively via SUB-D-connectors or parallel
screw terminal strips

3046 Home Road. Powell, OH 43065    P: (740) 917-5781    F: (740) 917-5791    www.GenesisAutomationOnline.com     [email protected] 

 www.GenesisAutomationOnline.com 

Summary of Contents for PU 210

Page 1: ...Z and A B Z likewise adjustable to either RS422 format or TTL level or HTL 10 30V level Potential separation between input and output Conversion of a A B quadrature direction signal to a static direct...

Page 2: ...cations and Design updates Table of Contents 1 Safety Instructions and Responsibility 3 1 1 General Safety Instructions 3 1 2 Use according to the intended purpose 3 1 3 Installation 4 1 4 Cleaning Ma...

Page 3: ...erve the right to modify the hardware software or operation manual at any time and without prior notice Therefore there might be minor differences between the unit and the descriptions in operation ma...

Page 4: ...cross sections for wiring are described in the Technical Specifications Before first start up it must be ensured that all connections and wires are firmly seated and secured in the screw terminals Al...

Page 5: ...n the power supply voltage 5 to 30 volts DC Inputs and outputs are isolated via inductive high speed couplers All signals can be connected alternatively via SUB D connectors or by parallel screw termi...

Page 6: ...op approx 1 5 volts i e 24 VDC power supply will result in a 22 5 V output swing The supply voltage can either be applied to the screw terminals marked GND and VIN on terminal strip X4 or also to the...

Page 7: ...erted signal must be connected A A B B Z Z Acceptable input level of differential signals 3 30 volts Setting of the input format is separately for each of the encoder channels according to above indic...

Page 8: ...nd are only conditionally suitable for signal transmissions under industrial EMC environment With standard applications please never touch the DIL switch hidden behind the front plate 4 2 Output level...

Page 9: ...re only relevant with single channel input signals input A alone or A with B as a static direction information when this information needs to be converted into a quadrature A B format at the output In...

Page 10: ...Pu21003b_oi_e doc Apr 16 Page 10 11 5 Dimensions 102 4 016 91 3 583 82 5 3 248 102 4 016 22 5 0 886 1 2 3 4 5 6 7 8 OFF ON 1 2 3 4 5 6 7 8 OFF ON Side view Top view Front view 82 5...

Page 11: ...e 9 pin Incremental outputs Number of outputs Signal level Channels Output current Output circuit Signal propagation delay Connections 1 3 5 28 5 V A A B B Z Z max 30 mA per output Push Pull approx 60...

Reviews: