CT34002a_e.doc / Nov-15
Page 31 / 42
7.2.
Outputs
No.
Output
Terminal
K1
Error:
This output goes high when an error is detected during operation
(see section 7.4 “Error Messages”).
X2 / 26
K2
Alert:
Indicates that the cutting roll, with respect to its profile position
set point, actually runs with a positive or negative position error
higher than the limit set at parameter „Alarm Level“.
X2 / 25
K3
Automatic Operation:
Set to on during automatic cutting operation while command
“Start” is set. When the “Start” command is released, this output
is set to off not before the actual cut is finished and the cutting
roll has come to standstill at its home position.
X1 / 10
K4
Homing Done:
Set to on when the homing cycle is finished. Reset to off when
the home position is no more valid and a new homing cycle
should be executed (after Jog, parameter set up or power down).
X1 / 9
–
Home*:
Indicates that the cutting roll is in its home position like defined
by register “Home Window”.
–
–
Virt. Cutting Pulse*:
The rising edge of this signal indicates the virtual cutting pulse at
the cutting position of the knife (see parameter “Cutting Pulse
Offset”).
The output is reset to low at the end of the synchronous zone
after the cut (see parameter “Sync. After Cut”).
–
–
Max. Frequency*:
Indicates that the line speed (line encoder frequency) has
exceeded its maximum value as defined by parameter “Max.
Master Frequency”.
–
–
Unit Ready*:
Indicates that the unit is ready to operate after power-up,
initialization and successful self-test.
–
*) Serial readout only (displayed at PC by OS3.2 operator software)