6.2.4.
Definitions for the Slave Encoder
F04
Range
Default
F04.032 Encoder properties
0 … 3
1
0= Impulses A, /A, B, /B (2 x 90°) incl. inv.
1= Impulses A, B (2 x 90°) without inv.
F04.033 Edge counting
0 … 2
0
0= Simple (x1)
1= Double (x2)
2= Full quadrature (x4)
F04.034 Counting direction
0 … 1
0
0= Up when A leads B
1= Down when A leads B
F04.035
n.a.
n.a. = not applicable
6.2.5.
Analogue output definitions
F05
Range
Default
F05.038 Control characteristics and analogue format
0 … 3
0
0= Output scaled for a -10 volts … +10 volts signal
1= Output scaled for a -10 volts … +10 volts signal
2= Output scaled for a -20 mA … +20 mA signal
3= Output scaled for a -20 mA … +20 mA signal
F05.039 Offset Correction:
Digital setting of analogue offset on correction signal.
-10.000 … +10.000
(volts)
0.000
F05.040 Gain Correction:
Digital setting of the proportional gain of the control
loop. Setting to 2.048 results in a response of 1 mV
per error bit. Recommended setting: 0.500...5.000
(Gain Correction / 2048 = x.xxx volts per error bit).
0 … 51.200
2.000
F05.041 Max. Correction:
Limitation of the output voltage of the correction
signal (correction will not exceed this setting)
0 … 10.000
(volts)
2.000
F05.042 Offset Total:
Digital setting of analogue offset of the overall
analogue output signal.
-10.000 … +10.000
(volts)
0.000
F05.043 Gain Total:
Sets the full-scale output voltage at maximum master
frequency (see parameter F02.013 Max. Master
Frequency), i.e. 9,000 means 9 volts at max. frequency
0 … 99.999*
(volts)
10.000
*) The real analogue output voltage is physically limited to 10 V