78
Chart 15—Programming/Tuning Failure
ATE Test
Normal
Yes
Yes
Yes
No
No
No
No
Yes
Yes
Yes
Yes
No
Yes
No
No
No
No
Yes
No
Yes
Start
Is
the VRS750 in ATE
Test or Normal Mode?
Is 13.8V
supplied to the test
box?
Is the mobile radio
powered on?
Is the SRIB
connected to the computer
and powered on?
Plug the 25 pin connector
into the SRIB and the 18
pin connector into the
VRS750.
Is the
Flashing Adapter being
used?
Connect the SRIB to the
serial port of the
computer using a null
modem cable and make
sure it is turned on.
Verify that P101-7 is
connected to J30-24.
Is the SRIB
connected to the computer
and powered on?
Disconnect the
programming cable from
the VRS750.
Did
the mobile radio
reset?
Plug the
programming cable
back in to the
VRS750 and try
again.
Reset the mobile
radio.
Plug the programming
cable back in to the
VRS750.
Is "PROG
VRS" displayed on the mobile
control head?
Try
programming
again.
A.
Connect the SRIB to the
serial port of the
computer using a null
modem cable and make
sure it is turned on.
Verify that the
mobile is
powered on. If
not, power the
mobile on and
start over.
A.
Is
the VRS750
programming cable
securely plugged into the
VRS750 and an
SRIB?
Supply 13.8V to the
VRS750 test box.
Is
"PROG VRS"
displayed on the mobile
control head?
Power on the
mobile radio.
Is the
switch in the B
position?
Remove the flashing
adapter and cycle
power to the VRS750.
Place the switch in the B
position and cycle power to
the VRS750. The A position
is for flashing only.
Cycle power to the VRS750
and try again. If the problem
persists, try a different
programming cable.
PROGRAMMING AND
TUNING ISSUES
Summary of Contents for VRS750