Power Supply
Use only a Motorola/Symbol approved power supply output rated at 12 Vdc and minimum 3.33 A.
The power supply shall be Listed to UL/CSA 60950-1; and certified to IEC60950-1 and EN60950-1
with SELV outputs. Use of alternative power supply will invalidate any approval given to this device
and may be dangerous.
Batteries
Charging
To charge the mobile device battery, the battery and charger temperatures must be b 32 º F
and + 104 º F (0 º C and + 40 º C).
Please follow the local regulations when disposing of re-chargeable batteries.
Taiwan - Recycling
EPA (Environmental Protection Administration) requires dry battery
producing or importing firms in accordance with Article 15 of the Waste
Disposal Act are required to indicate the recycling marks on the batteries
used in sales, giveaway or promotion. Contact a qualified Taiwanese
recycler for proper battery disposal.
Battery Information
Motorola/Symbol rechargeable battery packs are designed and constructed to the highest standards
within the industry.
However, there are limitations to how long a battery can operate or be stored before needing
replacement. Many factors affect the actual life cycle of a battery pack, such as heat, cold, harsh
environmental conditions and severe drops.
When batteries are stored over six (6) months, some irreversible deterioration in overall battery
quality may occur. Store batteries at half of full charge in a dry, cool place, removed from the
equipment to prevent loss of capacity, rusting of metallic parts and electrolyte leakage. When storing
batteries for one year or longer, the charge level should be verified at least once a year and charged
to half of full charge.
Replace the battery when a significant loss of run time is detected.
Standard warranty period for all Symbol batteries is ninety (90) days, regardless if the battery was
purchased separately or included as part of the scanner.
Battery Safety Guidelines
•
Use only genuine Motorola batteries.
•
The area in which the units are charged should be clear of debris and combustible materials or
chemicals. Particular care should be taken where the device is charged in a non commercial
environment.
•
Follow battery usage, storage, and charging guidelines found in the user's guide.
•
Improper battery use may result in a fire, explosion, or other hazard.
•
To charge the mobile device battery, the battery and charger temperatures must be b32
ºF and +104 ºF (0 ºC and +40 ºC).
•
Do not use incompatible batteries and chargers. Use of an incompatible battery or charger may
present a risk of fire, explosion, leakage, or other hazard. If you have any questions about the
compatibility of a battery or a charger, contact Motorola Enterprise Mobility support.
•
For devices that utilize a USB port as a charging source, the device shall only be connected to
products that bear the USB-IF logo or have completed the USB-IF compliance program.
•
Do not disassemble or open, crush, bend or deform, puncture, or shred.
CAUTION
Risk of explosion if battery is replaced by an incorrect type.
Dispose of batteries according to instructions.