Serial Interface
8 - 3
Serial Host Parameters
Various serial hosts use their own parameter default settings. Selecting standard, ICL, Fujitsu, Wincor-Nixdorf
Mode A, Wincor-Nixdorf Mode B, OPOS/JPOS, Olivetti, Omron, or Common Use Terminal Equipment
(CUTE-LP/LG bar code readers) sets the defaults listed in
Table 8-2
.
Table 8-2
Terminal Specific RS-232
Parameter
ICL
Fujitsu
Wincor-
Nixdorf
Mode A
Wincor-Nixdorf
Mode B/
OPOS/JPOS
Olivetti
Omron
CUTE
Baud Rate
9600
9600
9600
9600
9600
9600
9600
Parity
Even
None
Odd
Odd
Even
None
Even
Stop Bits
One
One
One
One
One
One
One
ASCII Format
8-Bit
8-Bit
8-Bit
8-Bit
7-Bit
8-Bit
7-Bit
Hardware
Handshaking
RTS/CTS
Option 3
None
RTS/CTS
Option 3
RTS/CTS
Option 3
None
None
None
Software
Handshaking
None
None
None
None
ACK/NAK
None
None
Serial Response
Time-out
9.9 Sec.
2 Sec.
None
None
9.9 Sec.
9.9 Sec.
9.9
Sec.
RTS Line State
High
Low
Low
Low = No data to
send
Low
High
High
Beep On <BEL>
Disable
Disable
Disable
Disable
Disable
Disable
Disable
Transmit Code ID
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Data Transmission
Format
Data/Suffix
Data/Suffix
Data/Suffix
Data/Suffix
Prefix/Data/
Suffix
Data/
Suffix
Prefix/
Data/
Suffix
Prefix
None
None
None
None
STX (1002)
None
STX
(1002)
Suffix
CR (1013)
CR (1013)
CR (1013)
CR (1013)
ETX (1003)
CR (1013)
CR
(1013)
ETX
(1003)
In the Nixdorf Mode B, if CTS is low, scanning is disabled. When CTS is high, scanning is enabled.
If you scan Nixdorf Mode B without connecting the decoder to the proper host, it may appear
unable to scan. If this happens, scan a different serial host type within 5 seconds of cycling power
to the decoder.
The CUTE host disables all parameter scanning, including Set Defaults. If you inadvertently select
CUTE, scan
*Enable Parameter Scanning (01h) on page 4-6
, then change the host selection.
Summary of Contents for PL3307
Page 1: ...PL3307 DECODER INTEGRATION GUIDE ...
Page 2: ......
Page 3: ...PL3307 INTEGRATION GUIDE 72E 149624 01 Revision 11 September 2011 ...
Page 6: ...iv PL3300 Decoder Integration Guide ...
Page 15: ...Table of Contents xiii Appendix E ASCII Character Sets Index ...
Page 16: ...xiv PL3307 Decoder Integration Guide ...
Page 20: ...xviii PL3307 Decoder Integration Guide ...
Page 44: ...3 4 PL3307 Decoder Integration Guide Figure 3 3 Imager Engine to PL3307 21 Pin Flex ...
Page 47: ...Accessories 3 7 Figure 3 6 PL3307 30 Pin Host Connector Molex 52437 Series ...
Page 49: ...Accessories 3 9 Figure 3 8 PL3300 microUSB Host Connector Molex 47346 Series ...
Page 52: ...3 12 PL3307 Decoder Integration Guide ...
Page 112: ...5 28 PL3307 Decoder Integration Guide ...
Page 168: ...8 8 PL3307 Decoder Integration Guide Baud Rate continued Baud Rate 460 800 Baud Rate 921 600 ...
Page 276: ...9 92 PL3307 Decoder Integration Guide ...
Page 278: ...10 2 PL3307 Decoder Integration Guide ...
Page 280: ...11 2 PL3307 Decoder Integration Guide ...
Page 298: ...B 8 PL3307 Decoder Integration Guide ...
Page 299: ...APPENDIX C SAMPLE BAR CODES Code 39 UPC EAN UPC A 100 123ABC 0 12345 67890 5 ...
Page 302: ...C 4 PL3307 Decoder Integration Guide QR Code US Postnet UK Postal ...
Page 334: ......
Page 335: ......