8 - 12 PL3307 Decoder Integration Guide
Hardware Handshaking
The data interface consists of a serial port designed to operate either with or without the hardware
handshaking lines
Request to Send
(RTS) and
Clear to Send
(CTS).
If Standard RTS/CTS handshaking is not selected, scan data transmits as it becomes available. Select
Standard RTS/CTS handshaking to transmit scan data according to the following sequence:
•
The decoder reads the CTS line for activity. If CTS is asserted, the decoder waits up to the Host Serial
Response Time-out for the host to de-assert the CTS line. If, after the Host Serial Response Time-out
(default) the CTS line is still asserted, the decoder sounds a transmit error and discards any scanned
data.
•
When the CTS line is de-asserted, the decoder asserts the RTS line and waits up to the Host Serial
Response Time-out for the host to assert CTS. When the host asserts CTS, data transmits. If, after the
Host Serial Response Time-out (default) the CTS line is not asserted, the decoder sounds a transmit
error and discards the data.
•
When data transmission completes, the decoder de-asserts RTS 10 msec after sending the last
character.
•
The host responds by negating CTS. The decoder checks for a de-asserted CTS upon the next
transmission of data.
During data transmission, the CTS line should be asserted. If CTS is deasserted for more than 50 ms between
characters, the decoder aborts transmission, sounds a transmission error, and discards the data.
If the above communication sequence fails, the decoder issues an error indication. In this case, the data is lost
and must be rescanned.
If hardware handshaking and software handshaking are both enabled, hardware handshaking takes
precedence.
•
None
: Scan this bar code to disable hardware handshaking.
•
Standard RTS/CTS
: Scan this bar code to select Standard RTS/CTS Hardware Handshaking.
•
RTS/CTS Option 1
: The decoder asserts RTS before transmitting and ignores the state of CTS. The
decoder de-asserts RTS when transmission completes.
•
RTS/CTS Option 2
: RTS is always high or low (user-programmed logic level). However, the decoder
waits for CTS to be asserted before transmitting data. If CTS is not asserted within Host Serial Response
Time-out (default), the decoder issues an error indication and discards the data.
•
RTS/CTS Option 3
: The decoder asserts RTS prior to any data transmission, regardless of the state of
CTS. The decoder waits up to Host Serial Response Time-out (default) for CTS to be asserted. If CTS is
not asserted during this time, the decoder issues an error indication and discards the data. The decoder
de-asserts RTS when transmission completes.
NOTE
The DTR signal is jumpered to the active state.
Summary of Contents for PL3307
Page 1: ...PL3307 DECODER INTEGRATION GUIDE ...
Page 2: ......
Page 3: ...PL3307 INTEGRATION GUIDE 72E 149624 01 Revision 11 September 2011 ...
Page 6: ...iv PL3300 Decoder Integration Guide ...
Page 15: ...Table of Contents xiii Appendix E ASCII Character Sets Index ...
Page 16: ...xiv PL3307 Decoder Integration Guide ...
Page 20: ...xviii PL3307 Decoder Integration Guide ...
Page 44: ...3 4 PL3307 Decoder Integration Guide Figure 3 3 Imager Engine to PL3307 21 Pin Flex ...
Page 47: ...Accessories 3 7 Figure 3 6 PL3307 30 Pin Host Connector Molex 52437 Series ...
Page 49: ...Accessories 3 9 Figure 3 8 PL3300 microUSB Host Connector Molex 47346 Series ...
Page 52: ...3 12 PL3307 Decoder Integration Guide ...
Page 112: ...5 28 PL3307 Decoder Integration Guide ...
Page 168: ...8 8 PL3307 Decoder Integration Guide Baud Rate continued Baud Rate 460 800 Baud Rate 921 600 ...
Page 276: ...9 92 PL3307 Decoder Integration Guide ...
Page 278: ...10 2 PL3307 Decoder Integration Guide ...
Page 280: ...11 2 PL3307 Decoder Integration Guide ...
Page 298: ...B 8 PL3307 Decoder Integration Guide ...
Page 299: ...APPENDIX C SAMPLE BAR CODES Code 39 UPC EAN UPC A 100 123ABC 0 12345 67890 5 ...
Page 302: ...C 4 PL3307 Decoder Integration Guide QR Code US Postnet UK Postal ...
Page 334: ......
Page 335: ......