The configuration file is encoded using an ASCII encoding scheme.
An example is show in
.
Figure 38
PTP 500 Example Configuration File
CAUTION:
The configuration file is currently restricted to a single software version and can
only be restored into a wireless unit operating the software version indicated in the configuration
file header.
The configuration file can also be used when swapping out a faulty wireless unit. If one of the
wireless units is replaced on a wireless link a configuration file captured from the faulty unit can
be uploaded into the new unit to speed up replacement. It should be noted that when placing
a configuration file into a wireless unit with a different MAC Address the license key will not be
restored and may need to be entered. This can be obtained either from the Quick Start Guide
supplied with the replacement wireless unit or directly from Motorola. Note that the target MAC
address at the other end needs to be changed to ensure that it is using the MAC address of the
replaced unit.
The restoration of configuration files can be performed using the Restore configuration tool. Using
the browser button to locate the configuration file you wish to restore then click the ‘Restore
Configuration File and Reboot’ button (
). The user will then be prompted to confirm
the action (
Summary of Contents for MOTOWI 4
Page 1: ...PTP 500 Series User Guide phn 1115 000v001 ...
Page 74: ...Web Page Reference 74 Figure 37 Save Configuration File Screen ...
Page 100: ...Web Page Reference 100 Figure 59 Spectrum Management as seen from the Master ...
Page 112: ...Web Page Reference 112 Figure 68 Remote Management ...
Page 197: ...Glossary 197 UTP Unshielded Twisted Pair VLAN Virtual Local Area Network ...