General Considerations
34
5 General Considerations
5.1
Spectrum Planning
The PTP 500 Series Bridge has four frequency variants in its product range.
Band
Definition
Frequency
Coverage
Variable Channel
Width
Channel
Raster
5.4 GHz
ETSI 5 GHz band B, USA UNII
Band
5470-5725 MHz
15 MHz
5 MHz
5.8 GHz
USA ISM Band / ETSI 5 GHz
band C
5725-5850 MHz
15 MHz
5 MHz
Table 5
PTP 500 Series Bridge Variants
Note:
for 5.4 GHz and 5.8 GHz, use of the product is allowed according to local regulations.
There are two distinct approaches to spectrum planning:
•
First an operator can utilize the default spectrum management mode i-DFS (intelligent Dy-
namic Frequency Selection). This mode uses the PTP 500 Series Bridge ability to measure the
interference levels in all channels to build up a picture of the interference / noise levels in all
channels. The PTP 500 Series Bridge uses statistical techniques to select the most appropri-
ate transmit and receive channels. i-DFS can be influenced in its channel decision process by
selectively barring channels from use. The use of this functionality is described in detail in
“Spectrum Management”.
•
Second, when detailed control of the spectrum allocation is required, it is recommended that
the fixed frequency mode is used to statically allocate transmit and receive channels.
Summary of Contents for MOTOWI 4
Page 1: ...PTP 500 Series User Guide phn 1115 000v001 ...
Page 74: ...Web Page Reference 74 Figure 37 Save Configuration File Screen ...
Page 100: ...Web Page Reference 100 Figure 59 Spectrum Management as seen from the Master ...
Page 112: ...Web Page Reference 112 Figure 68 Remote Management ...
Page 197: ...Glossary 197 UTP Unshielded Twisted Pair VLAN Virtual Local Area Network ...