OPERATING INSTRUCTIONS
4-32
M68HC11EVBU/D
VERF
Verify
4.6.18 Verify
VERIFY <host download command>
(NOT APPLICABLE TO EVBU)
VERIFY <T>
where:
<host download command> compare memory to host port download data.
<T> compare memory to terminal port download data.
NOTE
As equipped from the factory the EVBU only supports the VERF
<T> variation of the verify command.
The VERIFY command is similar to the LOAD command except that the VERIFY command
instructs the EVBU to compare the downloaded S-record data to the data stored in memory.
EXAMPLES
DESCRIPTION
>VERIFY T<CR>
Enter verify command.
Done
Verification completed.
>
>VERIFY T<CR>
Enter verify command.
Mismatch encountered.
error addr E000
Error message displaying first address that failed to
>
verify.
Refer to the downloading procedures at the end of this chapter for additional information
pertaining to the use of the VERF command.