HARDWARE PREPARATION AND INSTALLATION
M68HC11EVBU/D
2-7
In order to select the expanded-multiplexed, special-bootstrap, or special-test modes of operation,
remove the cut-trace short between pins 1 and 2 of jumper header J4,. Then install user-supplied
fabricated jumpers on jumper headers J3 and J4. Refer to Table 2-1 for directions when
configuring the desired EVBU M68HC11E9 MCU mode of operation.
Table 2-1. MCU Mode Select
J4
–
MODA
(1)
J3
–
MODB
MCU Mode Select
Installed
(2)
Removed
Single-Chip
Removed
(3)
Removed
Expanded-Multiplexed
Installed
(2)
Installed
Special-Bootstrap
Removed
(3)
Installed
Special-Test
NOTES
1. Installed jumper equals a logic 0 (shorted to ground), while a missing
jumper equals a logic 1 (open/pull-up).
2. The cut-trace short is present or a jumper is installed on J4.
3. The cut-trace short and jumper are removed from J4.
The EVBU can be reconfigured for either the single-chip, expanded-multiplexed, special-
bootstrap, or special-test modes of operation via jumper headers J3 and J4. For expanded-
multiplexed and special-test modes of operation, additional peripheral circuitry must be
implemented on the EVBU wire-wrap area to support the expanded modes. The EVBU can be
reconfigured for the special-bootstrap mode of operation without additional peripheral circuitry.
Summary of Contents for M68HC11EVBD
Page 4: ......
Page 92: ...HARDWARE DESCRIPTION 5 4 M68HC11EVBU D ...
Page 101: ...SUPPORT INFORMATION M68HC11EVBU D 6 9 Figure 6 2 EVBU Schematic Diagram Sheet 1 of 3 ...
Page 102: ...SUPPORT INFORMATION 6 10 M68HC11EVBU D ...
Page 103: ...SUPPORT INFORMATION M68HC11EVBU D 6 11 Figure 6 2 EVBU Schematic Diagram Sheet 2 of 3 ...
Page 104: ...SUPPORT INFORMATION 6 12 M68HC11EVBU D ...
Page 105: ...SUPPORT INFORMATION M68HC11EVBU D 6 13 Figure 6 2 EVBU Schematic Diagram Sheet 3 of 3 ...