GX2-PSAC10D -R Installation and Operation Manual
Section 2
Overview
The OmniStar GX2 platform provides increased rack density, reliability, ease of operation, and
computer-aided troubleshooting through the extensive use of status monitoring. Low time-to-repair
is facilitated because application modules are accessible and replaceable from the front of the
OmniStar GX2 equipment shelf. Fiber connections are also located in the front while RF and power
connections are located on the rear of the equipment shelf.
Basic components of the OmniStar GX2 system include:
Equipment shelf model GX2-HSG*
Control module GX2-CM100B
Power supply module GX2-PSAC10D-R or GX2-PSDC10D-R
A series of application modules to fit any system requirement
Figure 2-1 illustrates a front view of a fully populated GX2-HSG*:
F i g u r e 2 - 1
G X 2 - H S G * f u l l y p o p u l a t e d
The GX2-PSAC10D-R provides
+
5.1,
+
12, and
+
3.7 VDC power to the GX2-HSG* and all
application modules. The auto-sensing input-voltage feature recognizes 115 VAC or 230 VAC
applications. Surge protection for the input plus overcurrent protection for the output provide the
necessary safeguards for the power supply and the application modules served by it. A large heatsink
and integrated fans dissipate the internally generated heat and keep the module temperature within
acceptable limits.