background image

2

EX-3524/EX-3548 Layer 2 Gigabit Ethernet PoE/PoE+ Switch

MOTOROLA SOLUTIONS and the Stylized M Logo are registered in the US Patent & Trademark Office. © Motorola Solutions,
Inc. 2014. All rights reserved.

Summary of Contents for EX-3524

Page 1: ...Motorola Solutions EX 3524 EX 3548 Layer 2 Gigabit Ethernet PoE PoE Switch Installation Guide ...

Page 2: ...2 EX 3524 EX 3548 Layer 2 Gigabit Ethernet PoE PoE Switch MOTOROLA SOLUTIONS and the Stylized M Logo are registered in the US Patent Trademark Office Motorola Solutions Inc 2014 All rights reserved ...

Page 3: ...ord Specifications 9 2 4 1 Power Protection 9 2 5 Switch Description 9 2 5 1 Port LEDs 10 2 5 2 10 100 1000BASE T RJ 45 Ports 10 2 5 3 Gigabit SFP Slots 10 2 5 4 Mode Button 10 2 5 5 Console Port 10 2 5 6 System LEDs 10 2 5 7 Reset Button 10 2 5 8 Ground Point 10 2 5 6 AC Power Socket 11 2 6 LED Codes 12 2 6 1 System Status LEDs 12 2 6 2 Port Status LED 13 3 0 Hardware Setup 14 3 1 Rack Mount Inst...

Page 4: ... 24 4 1 Connecting to the Console Port 24 4 2 Resetting the Switch 25 5 0 Regulatory Information 26 5 1 Radio Frequency Interference Requirements FCC 26 5 2 Radio Frequency Interference Requirements Canada 26 5 3 CE Marking and European Economic Area EEA 27 5 4 Statement of Compliance 27 5 5 PSE Alarm 27 5 6 Power Cord Safety 28 5 7 Waste Electrical and Electronic Equipment WEEE 31 5 7 1 Turkish W...

Page 5: ...deploying EX 3524 and EX 3548 switches 1 1 Unpacking Verify that you have the equipment listed below EX 3524 or EX 3548 switch Rack Mounting Kit containing two brackets and eight screws for attaching the brackets to the switch Console cable RJ 45 to DB 9 Four adhesive foot pads EX 3524 EX 3548 Layer 2 Gigabit Ethernet Switches Installation Guide this document Inspect the equipment for damage If yo...

Page 6: ...ge due to a power surge or power failure Verify that the power connector and socket are accessible at all times during the operation of the equipment Do not work with power circuits in dimly lit spaces Do not install this equipment or work with its power circuits during thunderstorms or other weather conditions that could cause a power surge Verify there is adequate ventilation around the device a...

Page 7: ... Be sure to follow the guidelines listed below when choosing a site Locate the switch unit at the center of all devices you want to link and near a power outlet Maintain a temperature range within 0 to 50 C 32 to 122 F and humidity range within 10 to 90 non condensing Provide adequate space approximately 2 inches on all sides for proper air flow Confirm access for installing cabling and maintainin...

Page 8: ...2 x 16 10 x 1 73 in Weight EX 3524 3 6 kg 7 83 lb EX 3548 6 6 Kg 14 55 lb Operating temperature 0 C to 50 C 32 F to 122 F Operating humidity 10 to 90 non condensing Operating altitude EX 3524 4004 m 13 136 ft EX 3548 2000 m 6 561 ft Storage temperature 40 C to 70 C 40 F to 158 F Storage humidity 10 to 90 non condensing Storage altitude 4572 m 15 000 ft AC input voltage EX 3524 AC 100 240 V 50 60 H...

Page 9: ...ure to use a surge protection device between the electricity source and the EX 3524 EX 3548 switch Install an Uninterruptible Power Supply UPS A UPS provides continuous power during a power outage Some UPS devices have integral surge protection UPS equipment requires periodic maintenance to ensure reliability A UPS of the proper capacity for the data processing equipment must be purchased 2 5 Swit...

Page 10: ...Diag LED to display PoE status For more information see LED Codes on page 12 2 5 5 Console Port The RJ 45 connector on the front panel far right side that is labeled Console provides an out of band serial connection to a terminal or a PC running terminal emulation software The port can be used for performing switch monitoring and configuration For more information see Connecting to the Console Por...

Page 11: ...de 11 2 5 9 AC Power Socket The switch requires a 100 240 VAC 50 60 Hz AC power source For more information on the switch power input how to connect it and how to power on the switch see Power and Grounding on page 18 ...

Page 12: ...ribed in the following table LED Condition Status DIAG Green Solid Amber Solid Blinking Amber Blinking Amber and Green System diagnostic test completed successfully System diagnostic test in progress or PoE button pressed System fault detected System booting up PWR Green Solid Off Internal power operating normally No AC power is connected or the internal power supply has failed ...

Page 13: ... Blinking Amber On Blinking Green Off Port has a valid 10 100 Mbps link Blinking indicates traffic on the port Port has a valid 1000 Mbps link Blinking indicates traffic on the port The link is down PoE Statusa a Mode button is pressed On Amber Off A PoE device is connected No PoE device is connected Gigabit SFP Ports 25 28 or 49 52 Link Activity On Blinking Green Off Port has a valid 1000 Mbps li...

Page 14: ...ch cooling requirements Observe the following guidelines when selecting a location for switch installation Maintain a temperature of 0 to 50 C 32 to 122 F and non condensing humidity within 10 to 95 Provide space for adequate airflow Status LEDs should be clearly visible Ensure that twisted pair cables are always routed away from the power lines fluorescent lighting fixtures and other sources of e...

Page 15: ...Installation Guide 15 2 Use the supplied rack mounting screws to secure the switch in the rack 3 Connect an external AC power source to the AC power socket ...

Page 16: ...Ethernet cable for 10BASE T connections use 100 ohm category 5 or better Ethernet cable for 100BASE TX and 1000BASE T connections Install SFP transceivers and then connect fiber optic cabling to the transceiver ports Status LEDs should be clearly visible Ensure that twisted pair cables are always routed away from the power lines fluorescent lighting fixtures and other sources of electrical interfe...

Page 17: ...a flat surface 1 Attach the four adhesive feet to the bottom of the switch 2 Set the device on a flat surface near an AC power source making sure there are at least two inches of space on all sides for proper airflow 3 If installing multiple switches attach four adhesive feet to each switch Place each device squarely on top of the one below in any order ...

Page 18: ...ich the switch is to be mounted is properly grounded and in compliance with ETSI ETS 300 253 2 Ensure that there is a good electrical connection to the grounding point on the rack no paint or isolating surface treatment 3 Disconnect all power cables to the switch 4 The switch chassis is connected internally to 0 V This circuit is connected to the single hole grounding terminal on the rear panel of...

Page 19: ... select an appropriate transceiver type that is also compatible with the switch transceiver support 2 If the SFP slot is covered with a rubber protective cap remove the cap and keep it for later replacement 3 Insert the transceiver with the optical connector facing outward and the slot connector facing down Note that SFP transceivers are keyed so they can only be installed in the correct orientati...

Page 20: ... or 1000BASE T operation Check the following criteria against the current installation of your network Cable type Unshielded twisted pair UTP or shielded twisted pair STP cables with RJ 45 connectors Category 5 5e or better cable for 1000BASE T connections Category 5 or better for 100BASE TX connections and Category 3 or better for 10BASE T connections Protection from radio frequency interference ...

Page 21: ...rtain pairs of the connecting Ethernet cable For the EX 3524 the total PoE power delivered by all ports cannot exceed the 390 W power budget This means that up to 12 ports can supply a maximum 30 W of power simultaneously to connected devices or all 24 ports can supply a maximum of 15 4 W For the EX 3548 the total PoE power delivered by all ports cannot exceed the 779 W power budget This means tha...

Page 22: ...t 2 550 m 7 1805 ft LC 100BASE LX 9 125 micron single mode N A 2 m 10 km 7 ft 6 2 miles LC 10BASE LH 9 125 micron single mode N A 2 m 80 km 7 ft 50 miles LC NOTE The length of fiber optic cable for a single switched link should not exceed the relevant specified standards However power budget constraints should also be considered when calculating the maximum fiber optic cable length for a a particu...

Page 23: ...lead to degraded performance on the port 3 Connect one end of the cable to the SFP port on the switch and the other end to the SFP port on the other device Since SFP connectors are keyed the cable can be attached in only one orientation 4 As a connection is made check the Link LED on the switch to be sure that the connection is valid NOTE Ensure cables are properly secured and route them away from...

Page 24: ...PC s RS 232 serial DB 9 DTE COM port The serial port default settings are as follows Default Baud rate 115200 bps Character Size 8 Characters Parity None Stop bit One Data bits 8 Flow control None 4 1 Connecting to the Console Port To connect to the console port 1 Connect one end of the included RJ 45 to DB 9 serial cable to a DB 9 COM port connector on the network management computer 2 Plug in th...

Page 25: ...s 8 data bits 1 stop bit and no parity 4 Log in to the command line interface CLI using one of the default user login settings username admin password motorola or username guest password guest For a detailed description of connecting to the console and using the switch s command line interface CLI refer to the CLI Reference Guide NOTE The guest default user login will only allow a user to view swi...

Page 26: ...ault settings Press the reset button for 3 to less than 6 seconds to restart the system software using the current saved configuration file Press the reset button for 6 seconds or more to restart the system software using the factory default settings Press Button Duration Result Less than 3 seconds No change to settings From 3 seconds to less than 6 seconds Switch reboots using saved configuration...

Page 27: ...and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense 5 2 Radio Frequency Interference Requirements Canada This...

Page 28: ...must be carried out by qualified personnel only The unit must be connected to an earthed grounded outlet to comply with international safety standards Do not connect the unit to an A C outlet power supply without an earth ground connection The appliance coupler the connector to the unit and not the wall plug must have a configuration for mating with an EN 60320 IEC 320 appliance inlet The socket o...

Page 29: ...reil EN 60320 IEC 320 La prise secteur doit se trouver à proximité de l appareil et son accès doit être facile Vous ne pouvez mettre l appareil hors circuit qu en débranchant son cordon électrique au niveau de cette prise L appareil fonctionne à une tension extrêmement basse de sécurité qui est conforme à la norme IEC 60950 Ces conditions ne sont maintenues que si l équipement auquel il est raccor...

Page 30: ...en gemäß EN 60320 IEC 320 konfigurierten Geräteeingang haben Die Netzsteckdose muß in der Nähe des Geräts und leicht zugänglich sein Die Stromversorgung des Geräts kann nur durch Herausziehen des Gerätenetzkabels aus der Netzsteckdose unterbrochen werden Cordon électrique Il doit être agréé dans le pays d utilisation Etats Unis et Canada Le cordon doit avoir reçu l homologation des UL et un certif...

Page 31: ...les pour un cable flexible sont AWG No 18 ouAWG No 16 pour un cable de longueur inférieure à 2 mètres type SV ou SJ 3 conducteurs Le cordon doit être en mesure d acheminer un courant nominal d au moins 10 A La prise femelle de branchement doit être du type à mise à la terre mise à la masse et respecter la configuration NEMA 5 15P 15 A 125 V Danemark La prise mâle d alimentation doit respecter la s...

Page 32: ...a UE todos os produtos no fim de vida devem ser devolvidos à Motorola Solutions para reciclagem Para obter informações sobre como devolver o produto visite http www motorolasolutions com recycling weee Nederlands Voor klanten in de EU alle producten dienen aan het einde van hun levensduur naar Motorola Solutions te worden teruggezonden voor recycling Raadpleeg http www motorolasolutions com recycl...

Page 33: ... la Motorola Solutions pentru reciclare Pentru informaţii despre returnarea produsului accesaţi http www motorolasolutions com recycling weee Slovenski Za kupce v EU vsi izdelki se morajo po poteku življenjske dobe vrniti podjetju Motorola Solutions za reciklažo Za informacije o vračilu izdelka obiščite http www motorolasolutions com recycling weee Slovenčina Pre zákazníkov z krajín EU Všetky výro...

Page 34: ...time limits set forth in support agreements If you purchased your product from a Motorola Solutions business partner contact that business partner for support Customer Support Web Sites The Motorola Solutions Support Central Web site located at https portal motorolasolutions com Support US EN provides information and online assistance including developer tools software downloads product manuals an...

Page 35: ...Installation Guide 35 ...

Page 36: ... MOTOROLA MOTO MOTOROLA SOLUTIONS and the Stylized M Logo are trademarks or registered trademarks of Motorola Trademark Holdings LLC and are used under license All other trademarks are the property of their respective owners 2014 Motorola Solutions Inc All Rights Reserved MN000336A01 Revision A March 2014 ...

Reviews: