6809461A68
June 12, 2003
9
Level 1 and 2 Service Manual
Specifications
Specifications
General Function
Specification
Frequency Range GSM
880-915 MHz Tx (with EGSM)
925-960 MHZ Rx
Frequency Range DCS
1710-1785 MHz Tx
1805-1880 MHz Rx
Channel Spacing
200 kHz
Channels
174 EGSM, 374 DCS carriers with 8 ch.
per carrier
Modulation
GMSK at BT = 0.3
Transmitter Phase Accuracy
5 Degrees RMS, 20 Degrees peak
Duplex Spacing
45 MHz GSM, 95 MHz DCS
Frequency Stability
± 0.10 ppm of the downlink frequency
(Rx)
Operating Voltage
+3.0V dc to +5.1V dc (battery)
+4.4V dc to +6.5V dc (external
connector)
Average Transmit Current
300 mA max
Average Stand-by Current
7 mA max
Dimensions
107 mm x 45 mm x 19.5 mm
(4.2 inches x 1.7 inches x 0.76 inches)
Size (Volume)
80 cc (4.8 in
3
)
Weight
93 gm (2.9 oz)
Temperature Range
-10° C to +55° C (+15° F to +130° F)
Battery Life, 740 mAh Li Ion Battery
Talk time up to 640 minutes
Standby time up to 150 hours
All talk and standby times are
approximate and depend on network
configuration, signal strength, and
features selected. Standby times are
quoted as a range from DRX=2 to
DRX=9. Talk times are quoted as a range
from DTX off to DTX on.
Transmitter Function
Specification
RF Power Output
32 dBm nominal GSM 900
29 dBm nominal GSM 1800
30 dBm nominal DCS
Output Impedance
50 ohms nominal
Spurious Emissions
-36 dBm from 0.1 to 1 GHz,
-30 dBm from 1 to 4 GHz
Receiver Function
Specification
Receive Sensitivity
-107 dBm GSM 900,
-106 dBm GSM 1800,
-105 dBm DCS
RX bit error rate (100k bits) Type II
< 2%
Channel Hop Time
500 microseconds
Time to Camp
Approximately 5-10 seconds
Summary of Contents for E365
Page 1: ...Level 1 and 2 Service Manual E365 Dual Band Wireless Telephone E365 GSM 900 1800MHz ...
Page 2: ......
Page 4: ...4 June 12 2003 Table of Contents E365 ...
Page 18: ...18 June 12 2003 6809461A68 General Operation E365 ...
Page 42: ...42 June 12 2003 6809461A68 Part Number Charts E365 ...
Page 45: ......