36
June 12, 2003
6809461A68
Troubleshooting
E365
Troubleshooting Chart
Table 4. PF 0C27 Telephone: Level 1 and 2 Troubleshooting Chart
Symptom
Probable Cause
Verification and Remedy
1. Telephone will not turn on or stay on.
a) Battery either discharged or
defective.
Measure battery voltage across a 50 ohm (>1
Watt) load. If the battery voltage is <3.25 Vdc,
recharge the battery using the appropriate
battery charger. If the battery will not recharge,
replace the battery. If battery is not at fault,
proceed to b.
b) Battery terminals open or
misaligned.
Visually inspect the battery terminals on both
the battery and the telephone. Realign and, if
necessary, either replace the battery or refer to
a Level 3 Service Center for battery connector
replacement. If battery terminals are not at fault,
proceed to c.
c) Transceiver board defective.
Remove the transceiver board assembly.
Substitute a known good transceiver board and
temporarily reassemble the unit. Press the PWR
button; if unit turns on and stays on, disconnect
the dc power source and reassemble the phone
with the new transceiver board. Verify that the
fault has been cleared.
2. Telephone exhibits poor reception or
erratic operation such as calls frequently
dropping or weak or distorted audio.
a) Antenna defective
Check connection between the antenna and the
transceiver board. If the connection is OK,
substitute a known good antenna. If the fault is
still present, proceed to b.
b) Transceiver board defective.
Replace the transceiver board (refer to 1c).
Verify that the fault has been cleared and
reassemble the unit with the new transceiver
board.
3. Display is erratic, or provides partial or
no display.
a) Mating connections to or from
transceiver board faulty.
Check general condition of flex and flex
connector. If the flex and connector are good,
check that the display assembly mounting tabs
are fully engaged. If connector is not at fault,
proceed to b.
b) Transceiver board defective.
Replace the transceiver board (refer to 1c).
Verify that the fault has been cleared and
reassemble the unit with the new transceiver
board.
4. Incoming call alert transducer audio
distorted or volume is too low.
Faulty transceiver board.
Replace the transceiver board (refer to 1c).
Verify that the fault has been cleared and
reassemble the unit with the new transceiver
board.
5. Telephone transmit audio is weak.
(usually indicated by called parties
complaining of difficulty in hearing voice).
a) Microphone defective.
Replace the microphone as described in the
procedures. If fault is not cleared, proceed to b.
b) Transceiver board defective.
Replace the transceiver board (refer to 1c).
Verify that the fault has been cleared and
reassemble the unit with the new transceiver
board.
6. Receive audio from earpiece speaker is
weak or distorted.
a) Connections to or from transceiver
board defective.
Check connection from the earpiece to the
transceiver board. If connection is not at fault,
proceed to b.
Summary of Contents for E365
Page 1: ...Level 1 and 2 Service Manual E365 Dual Band Wireless Telephone E365 GSM 900 1800MHz ...
Page 2: ......
Page 4: ...4 June 12 2003 Table of Contents E365 ...
Page 18: ...18 June 12 2003 6809461A68 General Operation E365 ...
Page 42: ...42 June 12 2003 6809461A68 Part Number Charts E365 ...
Page 45: ......