Ground
2
-4
DSP56303 User’s Manual
2.2
Ground
Table 2-3. Grounds
Ground Name
Description
GND
P
PLL Ground—Ground dedicated for PLL use. The connection should be provided with an extremely
low-impedance path to ground. V
CCP
should be bypassed to GND
P
by a 0.47
µ
F capacitor located
as close as possible to the chip package.
GND
P1
PLL Ground 1—Ground dedicated for PLL use. The connection should be provided with an
extremely low-impedance path to ground.
GND
Q
(4)
Quiet Ground—An isolated ground for the internal processing logic. This connection must be tied
externally to all other chip ground connections, except GND
P
and GND
P1
. The user must provide
adequate external decoupling capacitors.
GND
A (4)
Address Bus Ground—An isolated ground for sections of the address bus I/O drivers. This
connection must be tied externally to all other chip ground connections, except GND
P
and GND
P1
.
The user must provide adequate external decoupling capacitors.
GND
D
(4)
Data Bus Ground—An isolated ground for sections of the data bus I/O drivers. This connection
must be tied externally to all other chip ground connections, except GND
P
and GND
P1
. The user
must provide adequate external decoupling capacitors.
GND
C
(2)
Bus Control Ground—An isolated ground for the bus control I/O drivers. This connection must be
tied externally to all other chip ground connections, except GND
P
and GND
P1
. The user must
provide adequate external decoupling capacitors.
GND
H
Host Ground—An isolated ground for the HI08 I/O drivers. This connection must be tied externally
to all other chip ground connections, except GND
P
and GND
P1
. The user must provide adequate
external decoupling capacitors.
GND
S
(2)
ESSI, SCI, and Timer Ground—An isolated ground for the ESSI, SCI, and timer I/O drivers. This
connection must be tied externally to all other chip ground connections, except GND
P
and GND
P1
.
The user must provide adequate external decoupling capacitors.
Note:
These designations are package-dependent. Some packages connect all GND inputs except GND
P
and
GND
P1
to each other internally. On those packages, all ground connections except GND
P
and GND
P1
are
labeled GND. The numbers of connections indicated in this table are minimum values; the total GND
connections are package-dependent.
Summary of Contents for DSP56303
Page 1: ...DSP56303 User s Manual 24 Bit Digital Signal Processor DSP56303UM AD Revision 1 January 2001 ...
Page 52: ...JTAG OnCE Interface 2 22 DSP56303 User s Manual ...
Page 114: ...General Purpose Input Output GPIO 5 10 DSP56303 User s Manual ...
Page 212: ...GPIO Signals and Registers 8 26 DSP56303 User s Manual ...
Page 268: ...Interrupt Equates A 22 DSP56303 User s Manual ...
Page 306: ...Programming Sheets B 38 DSP56303 User s Manual ...
Page 320: ...Index 14 DSP56303 User s Manual ...