Diagnostics
B
High-Definition DVR DCX3501-M
•
Installation Manual
64
365-095-16528-x.2
Field
Description
Frequency
From 54 to 860 MHz.
VCT ID
Virtual Channel Table ID
SOC
The Selectable Output control is enabled or disabled.
CCI
The copy control information:
00 — copy free
01 — no more copies
10 — copy once
11 — never copy
N/A — the value is invalid or cannot be retrieved
APS
The Analog Protection System; for example, Macrovision:
00 — no Macrovision
11 — Type 3 Macrovision
N/A — the value is invalid or cannot be retrieved
RC Flag
Displays whether the broadcast flag is present:
0 — no flag/not defined
1 — the flag is present/enabled
N/A — the value is invalid or cannot be retrieved
CIT
The constrained image trigger, as delivered in the PRK or the Set DRM API:
1 — set
0 — not set
N/A — the value is invalid or cannot be retrieved
DRM
The digital rights management valid flag bit:
1 — set
0 — not set
N/A—the value is invalid or cannot be retrieved
RS
The retention state:
Forever, 1 week, 2 days, 1 day, 12 hours, 6 hours, 3 hours, 90 minutes, or Not Defined
N/A —value is invalid or cannot be retrieved
SDV Client
Status
If Switched digital video is available, the following information is related to the SDV
Client:
•
Status of client
•
IP Address of primary switched video manager (SVM) server
•
IP Address of secondary switched video manager (SVM) server
•
IP Address of Auto Discovery server
•
SDV Mode
•
MotoCar configuration and message count