Diagnostics B-15
DCT700 Installation Manual
d 09: Upstream Modem (STARVUE II Diagnostics)
This diagnostic shows the status and operating parameters for the STARVUE II RF return:
STARVUE II DIAGNOSTICS
STATUS: DISABLED
FREQUENCY: 23.000
MHz
LEVEL: 39
IPPV: DISABLED
170 6-15-01
20:49:33
The STARVUE II Diagnostics fields are:
Field Description
Status
Indicates the transmitter status:
-
Idle
t
Transmitting
Frequency
Indicates the transmitting frequency.
Level
Indicates the approximate power value of the STARVUE II transmitter in dBmV. The
difference between the power value on the diagnostic screen and the actual power of the
STARVUE II module may be
±
5 dBmV.
IPPV
Indicates the Interactive Pay-Per-View status with the following variables:
ENABLED
IPPV enabled
UNSENT
−−−−
##
The set-top contains unsent IPPV transactions.
The variable
−
## is the
number of unsent transactions.
DISABLED
IPPV disabled
Last Line
Displays the sequence number, time, and date of the last poll message.
d 10: Application (APP) Code Modules
This diagnostic displays the currently downloaded code modules. This can be a multi-page
display. Press
SELECT
to display additional pages. This is an example of an OSD screen for a
set-top that contains ROM:
APP CODE MODULES
ASTB xxxx
aaa bbb
ccc
MODULE VER
STATUS
ID
0-8-0772
07.72
ENABLED
0001
Appl_____
02.00 DOWNLD 07DA