4-12
Diagnostics
DCT6200\DCT6208 Installation Manual
d04 In-Band (IB) Diagnostic
The IN-BAND DIAGNOSTIC displays for the last attempted tuned channel. If a digital carrier
is not present, this diagnostic indicates the carrier is not locked.
Table 4-12
IN-BAND DIAGNOSTIC - OSD
IN-BAND DIAGNOSTIC
MODE:
64
QAM
CARRIER LOCK:
YES
DATA:
YES
SNR 32.0
dB
GOOD
AGC: 23
%
FAIR
5 SECOND ERROR
COUNTS:
UNCORRECTABLE:
1234
CORRECTABLE:
5678
The display information is updated every 5 seconds when viewing the diagnostic.
Figure 4-5 illustrates the LED display:
Figure 4-5
IN-BAND DIAGNOSTIC - LED
MUTE
MUTE
P
IB diagnostic
indicator
Data activity
indicator
Carrier lock indicator
(L for locked,
U for not locked)