DCT5100 Installation Manual
Section 4
Diagnostics
This section describes the diagnostics designed to confirm proper installation of the DCT5100.
They include checking error states, signal integrity, and provisions to identify the DCT5100 on
the network and verify communications with the headend. The diagnostic information is
displayed on the front-panel LEDs and the On-Screen Display (OSD).
For diagnostics provided in this section:
All indicators are in decimal notation unless otherwise noted.
All signal-level and quality indicators are based on a 1% to 100% scale, unless otherwise
noted.
All sample displays are illustrative; actual data may differ from the examples.
Accessing Diagnostics
You can run the base platform software or Thin Client software to access the DCT5100
diagnostics. The Heritage mode and the Enhanced mode are the two modes of entry for
accessing diagnostics. The Heritage mode uses the front-panel keys or IR remote and is
commonly used with the DCT 1000, DCT 1200, and DCT2000 models. The Enhanced mode uses
the front-panel keys and supports an on/off state-independent entry.
To access diagnostics using the Heritage and Enhanced modes:
1
Ensure the set-top is installed with the base platform or Thin Client software and that it is
connected to an ac outlet.
2
Press
POWER
and then within 2 seconds press
SELECT
for Heritage mode.
or
Simultaneously press both
CURSOR
◄
and
CURSOR
►
and hold both keys for three seconds for
Enhanced mode.
The DIAGNOSTICS main menu is displayed on the OSD and d01 is displayed on the
front-panel LED. The DCT5100 is now in diagnostic mode.
Use the following keys to navigate diagnostics menus:
Press
CHANNEL
▲
,
CHANNEL
▼
,
CURSOR
▲
, or
CURSOR
▼
to select
d01
through
E
.
Press
CURSOR
◄
,
CURSOR
►
,
SELECT
or
ENTER
to execute the selected diagnostic.
Select
E
from the main menu to exit.
Pressing
POWER
also exits diagnostic mode.