Powerline MU
Page 29 of 112
•
RG6 Coax cable
•
Coax Splitters (must include 5-30 MHz in range). Number of splits and splitters
is determined by the number of cables and locations of coupler installation. If
possible, use bi-directional splitters. A possible source for bi-directional splitters
is the Radio Shack
®
2-way splitter (Model 15-2587) and the Radio Shack 4-way
splitter (Model 15-2588).
Maximum dB Loss Chart
Number of Splits
Maximum dB loss per split
2-way
-3.5
3-way
-5.7
4-way
-7.5
•
Conduit Fittings (compression connectors/setscrew couplings)
•
Cable Ties as needed
•
Rubber Grommets as needed
Procedure
1. Remove the panel of either the termination or distribution cabinets at the desired
location.
2. Determine number of couplers needed.
3. Determine the number of bi-directional splitters needed (if feeding multiple
cabinets).
4. Remove knock-out or create a small hole in the bottom or side of the cabinet.
5. Install conduit fitting in knock-out.
6. Mount the Gateway in the desired location. Be sure to note the distance between
the Gateway location and the location where the couplers will be installed.
7. After determining the length needed, create RG6 coax cable with standard F-
Connectors on each end.
8. Attach the F-Connector from one end of the cable to the back of the Gateway as
shown in Figure 12.
9. Attach the other F-Connector lead (from coax going to Gateway) to the inbound
port on the coax splitter. Attach terminators to any unused ports on the splitter.
10. Feed the coax end of the couplers through the conduit fitting and connect it to the
splitter.
11. Open the coupler by gently lifting on the latch on the housing. The housing is
hinged on the other side so it remains intact. The core itself will be in half, with
one half containing the insulated cable that will induce the RF signal onto the
electrical lines.
12. Connect one coupler to each phase in the cabinet, being sure the plastic case
latches securely together. Be sure the cable stays inside the core when latching.
Summary of Contents for 2700 - Car Cell Phone
Page 1: ...Powerline MU User Guide Powerline MU User Guide PowerlineMU UG en Issue 4 0 August 2007 ...
Page 19: ...Powerline MU Page 19 of 112 Figure 2 Electrical Symbols Figure 3 Sample Diagram A ...
Page 32: ...Powerline MU Page 32 of 112 Figure 14 Individually metered installation capacitive coupling ...
Page 109: ...Powerline MU User Guide March 2007 Issue 2 0 Page 109 of 112 Plug Types ...