Powerline MU User Guide
March, 2007
Issue 2.0
Page 100 of 112
100
Part Number
0171486N22
Part Name
Powerline MU Inductive Coupler 100
Description
Optional Powerline MU coupler to Induce Signal onto in-
building cables before the Meter Bank.
High Voltage Interface
Fits up to 2/0 AWG cable rated at 175A
Cable
75 Ohm Coaxial
Connectors
F-Connector (Coaxial)
Center Conductor
600v rated 22-guage stranded copper THHN wire
Dimensions
2.8 in x 2.3 in x 2.2 in (70.14 mm x 58.3 mm x 55mm)
Inner Diameter of core
.55 in (14 mm)
Outer Diameter of Core
2.02 in (51.31 mm)
Weight
1.05 lbs
Operating temperature
-40°C to 55°C (-40°F to 131°F)
Safety
UL authorization (In conjunction with Powerline MU Gateway)
Inductive Coupler Sizes
Column A lists the American Wire Gauge sizes, Column B lists Metric Wire Gauge sizes, and
Column C measures the outer diameter of the electric wire installed in the building. Use that
information to choose the recommended Powerline MU Inductive Coupler from Column D. Column
E lists the inner diameter (the ferrite core) of the Powerline MU Inductive Coupler.
A
Conductor Size
(American Wire
Gauge)
B
Conductor Size
(Metric Wire
Gauge, mm2)
C
Approx Conductor
Outer Diameter With
Insulation (mm)
D
Recommended
Powerline MU
Inductive Coupler
E
Powerline MU
Coupler Inner
Diameter (mm)
-
400
30.1
750*
31
750 MCM
-
29.4
750*
31
700 MCM
-
28.5
750*
31
600 MCM
-
26.7
750*
31
300
26.5
750*
31
500 MCM
-
24.9
500
25.4
-
240
24.2
500
25.4
400 MCM
-
22
500
25.4
-
185
21.1
500
25.4
350 MCM
-
20.6
500
25.4
300 MCM
150
18.5
500
19.4
250 MCM
-
17.8
250
19.4
-
120
17.5
250
19.4
4/0
-
16
250
19.4
-
95
15.4
250
19.4
3/0
-
14.7
250
19.4
-
70
13.7
100
14
2/0
-
13.5
100
14
1/0
-
12.2
100
14
-
50
12
100
14
* Powerline MU Inductive Coupler 750 will be available Q4 2007.
Summary of Contents for 2700 - Car Cell Phone
Page 1: ...Powerline MU User Guide Powerline MU User Guide PowerlineMU UG en Issue 4 0 August 2007 ...
Page 19: ...Powerline MU Page 19 of 112 Figure 2 Electrical Symbols Figure 3 Sample Diagram A ...
Page 32: ...Powerline MU Page 32 of 112 Figure 14 Individually metered installation capacitive coupling ...
Page 109: ...Powerline MU User Guide March 2007 Issue 2 0 Page 109 of 112 Plug Types ...