Motorline MLB2 User Manual Download Page 9

8A

8B

EN

EN

05. PROGRAMMING

05. PROGRAMMING

DELETE ALL USERS

DOOR RELAY SHOOTING TIME

These operations can only be done in 

Programming Mode

.

OPERATIONS

INSTRUCTIONS

• 

Delete all users

Master Code

2

#

(This device allows you to delete all users recorded with card, 

Fingerprint or both at once).

These operations can only be done in 

Programming Mode

.

OPERATIONS

INSTRUCTIONS

Door relay shooting time

Pulse Mode (The activation time of the relay for door ope-

ning can be set between 1 and 99 seconds).

Close Mode

#

0

3

(Switching the relay tripping time on / off).

1 a 99 #

4

*

When used with an optional magnetic contact or magnetic contact built into the lock, if the door is 

forced to open or is opened after 20 seconds, the internal bell and the alarm output will be active.

The alarm output time is adjustable from 1-3 minutes, the default time is 1 minute.

DOOR WARNING OPEN TOO LONG TIME (DOTL)

DOOR WARNING OPEN TOO LONG TIME (DOTL)

OPERATIONS

INSTRUCTIONS

• 

Turn off the Alarm

OPERATIONS

INSTRUCTIONS

• 

Turn off the Alarm

These operations can only be done in 

Programming Mode

.

OPERATIONS

INSTRUCTIONS

• 

Disable open door detection 

(default).

#

0

6

•  

Enable open door detection

#

1

6

These operations can only be done in 

Programming Mode

.

OPERATIONS

INSTRUCTIONS

• 

Set the alarm output time (Select be-

tween 1, 2 or 3 minutes).

#

(1~3)

5

When used with an optional magnetic contact or magnetic contact built into the lock, if the door is 

normally opened but not closed after 1 minute, the internal doorbell will be active automatically to 

remind people to close the door and continue to ring for 1 minute until it turns off automatically.

By default, Open Door Detection is disabled (60 #).

To turn off the alarm when it has been triggered, perform this step in Stand-By mode:

NOTICE OF FORCED DOOR OPENING

#

0

5

#

0

5

To turn off the alarm when it has been triggered, perform this step in Stand-By mode:

Summary of Contents for MLB2

Page 1: ...v2 0 REV 07 2019 MLB2 MLB2 EN INSTALLER AND USER S MANUAL...

Page 2: ...certain hazardous substances in electrical and electronic equipment Applicable in countries with recycling systems This marking on the product or literature indicates that the product and electronic...

Page 3: ...with experienced in terms of usage of the product in a safe manner and who understands the risks and dangers involved Children shouldn t play with the product or opening devices to avoid the motorize...

Page 4: ...esanyrepairormodification unlocktheautomatism turn off the power and do not use it until all safety conditions have been met In the event of tripping of circuits breakers of fuse failure locate the ma...

Page 5: ...acidade de cart o 2000 Users Fingerprint sensor Optical sensor Operating Temperature 40 60 C Identification speed 1s FAR 0 001 FRR 0 01 Identification time 1s Operating Humidity 20 90 Reading range 2...

Page 6: ...e screwdriver loosen the screw fully and remove the back cover FIX THE REAR COVER Insert the bushings position the cover in the holes and secure it with the screws ENCLOSURE THE MLB2 Attach the MLB2 t...

Page 7: ...STRUCTIONS Change Master Code New Code New Code 0 At first use of the device you must always change the master code for security and set the operating mode for authorization of access ID User number b...

Page 8: ...fingerprint User with card Read Card The device uses an LDR light dependent resistor as an anti theft alarm If the keyboard is removed from the cover the tampering alarm will be activated ANTI THEFT...

Page 9: ...e is 1 minute DOOR WARNING OPEN TOO LONG TIME DOTL DOOR WARNING OPEN TOO LONG TIME DOTL OPERATIONS INSTRUCTIONS Turn off the Alarm OPERATIONS INSTRUCTIONS Turn off the Alarm These operations can only...

Page 10: ...arily for banks prisons and other places where top level security is required 01 Add Users to both MLB2 02 Set both readers to the lock function 01 Turn off the power to the device 02 Continuously pre...

Page 11: ...Common Relay 4 DC Red Power Input 12Vdc Input DC 5 OPEN Yellow One end of the output button Output button of the other end connected GND 6 D_IN Brown One end of the magnetic switch magnetic end switch...

Page 12: ...O NC COM MLB2 Red Yellow Brown Gray Green White Black Blue Orange Purple Magnetic Switch Exit key PUSH GND 12V NC NO GND COM Power Supply 12Vdc 5A Power Supply 12Vdc 3A Bell 24Vdc 20A m x EF380 12Vdc...

Page 13: ...OPEN D_IN ALARM D0 D1 GND NO NC COM MLB2 Magnetic Switch Exit key Red Yellow Brown Gray Green White Black Blue Orange Purple Red Yellow Brown Gray Green White Black Blue Orange Purple 12Vdc OPEN D_IN...

Page 14: ...y too dry blow on the finger and retry FINGERPRINT IS VERIFIED BUT AUTHORIZATION KEEPS FAILING 1 Check whether the user is restricted by door zone or time zone 2 Check with administrator whether the e...

Reviews: