background image

v1.0

REV. 12/2019

SIGMA

EN

USER / INSTALLER'S MANUAL

SIGMA

Summary of Contents for SIGMA 4M

Page 1: ...v1 0 REV 12 2019 SIGMA EN USER INSTALLER S MANUAL SIGMA...

Page 2: ...le in countries with recycling systems This marking on the product or literature indicates that the product and electronic accessories eg Charger USB cable electronic material controls etc should not...

Page 3: ...y persons with experienced in terms of usage of the product in a safe manner and who understands the risks and dangers involved Children shouldn t play with the product or opening devices to avoid the...

Page 4: ...mrequiresanyrepairormodification unlocktheautomatism turn off the power and do not use it until all safety conditions have been met In the event of tripping of circuits breakers of fuse failure locate...

Page 5: ...lashlight 2 FALK remote controls Unlock key Barrier Gate Key MF30 Photocells User Manual Bar mounting accessories Barrier fixing plate Barrier Fixed support for bar Barrier bar SIGMA is an electromech...

Page 6: ...the opening maneuver PERMANENT BLUE LIGHT During the pause time while open FLASHES RED LIGHT During the closing maneuver PERMANENT YELLOW LIGHT When the barrier is closed and the twilight sensor dete...

Page 7: ...The map shown is for a standard installation however we do not provide all components see kit composition on page 4B If you need other accessories please contact us 1 Sigma 2 Bar 3 Bar Extension 4 Pho...

Page 8: ...Move the cover lever to the right as shown to unlock the cover Remove Side Profiles Do the same with the side and chrome profiles to fully release the inside of the barrier If you already have a shoe...

Page 9: ...izontal Once the cement has dried remove the upper females to apply the barrier Route the electrical cables to connect the engine to the accessories and power supply Leave cables of a length that ensu...

Page 10: ...ed position 3 Disconnect the bar from any power supply These safety steps ensure that the springs are at the lowest point of tension and that the bar will not come down close by itself REMOVE LEVER SP...

Page 11: ...nto the side hole and replace the bolt and female bolt NOTE Fully tighten the bolt and then unscrew it 1mm to loosen slightly Retighten the motor tip to the lever in one of the holes on the other side...

Page 12: ...vided in the package Keep the attached cables inside the bar cover and secure the cover to the barrier with the two remaining screws Apply the label to hide the screws 4 2 3 REVERSE BAR SUPPORT 1 Make...

Page 13: ...ned to the height of the bar you will have to adjust the arm height To do this follow these steps Drill two holes in the installation location to secure the support with screws and dowels Loosen the s...

Page 14: ...ith pliers so that it does not rotate and then tighten the adjusting female until each spring is stretched the distance mentioned in the table on page 14 Once the spring s are stretched unlock the mot...

Page 15: ...5 mm 1 mm MOTOR Hole Hole Hole 3 Hole 3 Hole 3 Hole 3 Hole 3 BAR WITH RUBBER 6000 5500 5000 4500 4000 3500 SPRING 1 Big Hole Hole 3 Hole 3 Hole 3 Hole 3 Hole 3 Hole 3 Adjustment 15 mm 1 mm 20 mm 1 mm...

Page 16: ...shaft inward Place the bar in a horizontal closed position After adjusting the screw tighten the locking female until it touches the center lever to lock the screw in this position 1 3 2 4 Lock femal...

Page 17: ...the connectors top of the barrier Route the power cables coming from the ground through the pipe When the power cable reaches the barrier surface connect the wires to the connector on the electronics...

Page 18: ...frame Use the slots on the top and bottom plates of the chassis to guide the side profiles and keep them in this position 1 2 APPLY COVER Connect the flashing light LEDs plug with the connection plug...

Page 19: ...ule Barrier cover LED Strip Flashing Light Engine SIGMA Barrier Transformer Control board MC61 BR Barrier Interior Limit Switch Brown Blue Black Red Red Green Yellow Black Color wires Color wires Engi...

Page 20: ...COM NC NO 1 2 1 2 3 4 COM NC NO 1 2 EN 04 CONNECTIONS PHOTOCELL CONNECTIONS AND SAFETY BAND Control board MC61 BR Barrier Interior Control board MC61 BR Barrier Interior Blue Red Green Yellow Brown Wh...

Page 21: ...nosis Barrier opens but doesn t close 1 Check if there is any obstacle in front of the photocells 2 Make sure if the photocells are working Put your hand in front and check that the relay makes the sa...

Reviews: