background image

5

500mm

350mm

300mm

1

5

2

3

4

200mm 180mm

180mm 200mm

EN

02

 • 

 Drill a hole in the ground to create a concrete foundation. The dimensions presented

are recommended in foundation creation. You should leave tubes in the middle for the 

passage cables for power and accessories.

04

 • 

Apply the column with the screws to the concrete base. You must ensure that the 

column is level (use a level).

GROUND

NUTS

SCREWS

NUTS

CHAINLIFT

CHAINLIFT

CHAINLIFT

VÃO

03. INSTALLATION

OPERATOR INSTALLATION

For the correct functioning of the automatism, it is necessary to take into

the dimensions mentioned in the image. Leave a 200mm free space on the 

door side of each automatism, so you can open the automatism door

whenever necessary.

05

 • 

Proceed in the same way to install the second column of the automatism.

01

 • 

Measure the desired distance from one column to another automatism column 

(chain length) before installation.

CEMENT SHOULD

BE FRESH

INSTALLATION OF 

THE CHAIN 

EXISTING FOUNDATION

*If you are installing the automatism

in an existing foundation, screw the

fixing plate to the floor, using

suitable screws and bushings

(not supplied in the kit).

INSTALLATION OF 

THE GUTTER

03

 • 

Fill the hole with concrete and smooth the top where you will fix the column.

Summary of Contents for CHAINLIFT

Page 1: ...v2 1 REV 02 2022 CHAINLIFT CHAINLIFT EN USER INSTALLER MANUAL...

Page 2: ...o promote the sustainable reuse of material resources Home users should contact the dealer where they purchased this product or the National Environment Agency for details on where and how they can ta...

Page 3: ...without any knowledge of the product provided that these are supervision and instructions given by persons with experienced in terms of usage of the product in a safe manner and who understands the r...

Page 4: ...the product in an emergency If the system requires any repair or modification unlock the automatism turn off the power and do not use it until all safety conditions have been met In the event of trip...

Page 5: ...c Power 100W Absorbed current 4 A RPM 60RPM Noise LpA 50dB A Operating temperature 25 C 55 C IP IP65 Working Frequency 80 Maximum chain weight 20kg 20 mt iron chain On the package you will find the fo...

Page 6: ...utomatism it is necessary to take into the dimensions mentioned in the image Leave a 200mm free space on the door side of each automatism so you can open the automatism door whenever necessary 05 Proc...

Page 7: ...to give resistance If you choose another type of gutter gutter A you will need to make a foundation to fix it on the ground Gutter B Gutter A INSTALLATION OF THE CHAIN 06 Secure the chain in one of t...

Page 8: ...control board Changing the wires in the battery changes the direction of movement of the motor The test must be carried out by specialized technicians due to the serious danger related to the misuse...

Page 9: ...our MOTORLINE technical services for diagnosis 1 If the motor works the problem is from control board Pull it out and send it to our MOTORLINE technical services for diagnosis 2 If the motor doesn t...

Reviews: