background image

                                                                  

MOTOMA POWER CO., LTD 

Http: //  www.motoma.com     

E-mail: [email protected] 

 

Manufacturer reserves the right to alter or amend the design, model and specification without prior notice. 

 

5 / 7 

 

 

After standard charged,  and stand  for 14 days, No leakage nor  deformation.

 

5.15 Humidity Test 

After Standard charged, then  stand for 14 days at 33±3

 and RH=80±5%, No leakage. 

  

5.16 Storage Recommendation 

The battery can be stored at a temperature  range of -20~30

 for normal  storage or prolonged 

storage, and at a maximum relative humidity  of 85%.   

One recovery  charging (ref to 5.2) is recommended for every 6 months of storage, in order to 

protect the battery  quality performance.

 

 

6.  ENVIRONMENTAL PROTECTION REQUIREMENT

 

6.1 The requirement  on Hazardous  Substances in the materials should comply  with MOTOMA’s 

standard  on HSF (Hazardous  Substance Free). 

6.2 The requirement  on Hazardous  Substances in the Products should comply with 2006/66/EC 

and MOTOMA’s  standard  on HSF. 

 
7. TRANSPORT 

7.1 To ensure battery safety during delivery, SOC (State of charge) must be below 30% , inside 

temperature  of container could not be over 35

. Product holder should be responsible for any 

possible loss during delivery if above conditions cannot be met completely. 

7.2 Inside temperature of container must be below 20

  if any client requires SOC above 35%,the 

distance between battery master cartons not less than  10cm in container, and coercive air cross 

ventilation  system is required in container to ensure even  temperature  for each master carton. 

Product holder should be responsible for any possibly accidental loss if above conditions cannot 

be met completely. 

 

8.

 

WARNING !

 

  Do not apply water, seawater or other oxidizing reagents to MOTOMA  batteries, as this can 

caused rust and heat generation. If a battery becomes rusted, the gas release vent may no 

longer  operate, and can result in explosion. 

  Do not  over-charge  MOTOMA  batteries, If MOTOMA  batteries are not  fully  charged after the 

battery charger’s predetermined charging period has clasped, stop the charging  process. 

Prolonged charging may cause leakage of battery fluid, heat generation, and explosion.  Be 

sure  to handle  recharged batteries carefully  as they may be not. 

  MOTOMA  batteries contain a strong alkaline solution  (electrolyte).If  the skin or clothing comes 

in contact with fluid from a MOTOMA battery; thoroughly wash the area immediately with clean 

water from the tap or another source. Battery fluid can irritate the skin. 
 

  Do not connect more than 21pcs MOTOMA batteries in series, as this may cause electrical 

Summary of Contents for NH-4-5SC1400P

Page 1: ...O DSE NH 4 5SC1400P10 V20A EDITION V20A DATE 2020 11 24 Prepared By Checked By Approved By QE1 QE A MOTOMAPOWER CO LTD Http www motoma com E mail info motoma com Manufacturer reserves the right to alt...

Page 2: ...for 2 4hours V 5mV 3 5 End voltage of discharge 1 0V 3 6 Operate temperature range relative humidity 45 85 Standard charge 0 45 Quick charge 10 40 Rapid charge 10 30 Discharge 10 50 3 7 Storage relat...

Page 3: ...BLE I Discharging performance at 20 Constant Discharge Current Rate Constant Discharge Current End Point Voltage Discharge Duration Available Capacity 3 0C 4 2A 0 8V 19min 95 5 0C 7 0A 0 8V 10 8min 90...

Page 4: ...ing After standard charged charge battery at 42mA 70mA for 28 days no fire or no explosion 5 10 2 Forced discharge The discharged battery is subjected to a reverse charge at 1400mA for 90 minutes no f...

Page 5: ...ry if above conditions cannot be met completely 7 2 Inside temperature of container must be below 20 if any client requires SOC above 35 the distance between battery master cartons not less than 10cm...

Page 6: ...charger or the equipment during used Be sure to use the recommended charging method for MOTOMA batteries read the battery charger s instruction manual carefully Do not use old and new batteries mixed...

Page 7: ...harging the battery unit The data sheet is for reference only and should not be used as a basis for product described guarantee or warranty Nominal voltage V 1 2 Capacity Typical 1400mAh Minimum 1400m...