5.1 Testing conditions 

The battery shall be evaluated within 1 month from the arrival date. 

Unless otherwise stated in these specifications, the battery  to be tested shall be stored for not 

more than  1 hour  at an ambient  temperature  of 20±5

  and relative humidity  of 65±20%. 

   

5.2 Charging procedure for test purpose 

      The battery  shall  be charged at an ambient  temperature of 20±5

  at a constant  current  of   

140mA

 (0.1C) for 15 hours. 

5.3 Terminal voltage (O.C.V) 

Open circuit voltage shall be a minimum voltage of 1.25V within 14 days after being standard 

charged. 

5.4 Internal resistance 

Within 1 hour  after being standard charged, the internal  resistance is not greater than 

10m

Ω

,   

as tested by 1000Hz AC source. 

   

5.5 Discharging performance   

TABLE I: Discharging  performance  at 20

 

Constant Discharge 

Current Rate   

Constant Discharge 

Current 

End Point 

Voltage 

Discharge 

Duration 

Available 

Capacity 

3.0C 

4.2A 

0.8V 

19min 

95% 

5.0C 

7.0A 

0.8V 

10.8min 

90% 

10.0C 

14.0A 

0.8V 

4.8min

 

80% 

Note:

 

All the testing should be done within  1 hour after being standard charged.

 

5.6 Temperature characteristics 

TABLE 2: Temperature  Characteristics 

Standard Charge 

Temperature   

Discharge 

Temperature 

Constant Discharge 

Current 

End Point 

Voltage 

Discharge 

Duration 

Available 

Capacity 

40

 

20

 

280mA 

1.0V 

210min 

70% 

20

 

0

 

280mA 

1.0V 

210min 

70% 

 

5.7 Charge retention 

In  the charge retention  test, the cell shall  be standard charged as 

5.2

, and shall be stored in 

open circuit for 28 days at 20±5

 (RH=65±20%),  and the battery  shall be discharged at the  same 

condition  at a current  of 

280mA

 to 1.0V, discharge time shall  be a minimum  of 180 minutes. 

  

5.8

 

Overcharge

 

The test should  be done within  1 hour  after  charged at a current  of 

140mA

 for 48 hours,  the  battery 

shall  be discharged at 20

, at a current  of 

280mA

 to 1.0V, discharge time shall be a minimum of 300 

minutes.

 

5.9

 

Endurance in  cycles

 

Summary of Contents for NH-4-5SC1400P

Page 1: ...O DSE NH 4 5SC1400P10 V20A EDITION V20A DATE 2020 11 24 Prepared By Checked By Approved By QE1 QE A MOTOMAPOWER CO LTD Http www motoma com E mail info motoma com Manufacturer reserves the right to alt...

Page 2: ...for 2 4hours V 5mV 3 5 End voltage of discharge 1 0V 3 6 Operate temperature range relative humidity 45 85 Standard charge 0 45 Quick charge 10 40 Rapid charge 10 30 Discharge 10 50 3 7 Storage relat...

Page 3: ...BLE I Discharging performance at 20 Constant Discharge Current Rate Constant Discharge Current End Point Voltage Discharge Duration Available Capacity 3 0C 4 2A 0 8V 19min 95 5 0C 7 0A 0 8V 10 8min 90...

Page 4: ...ing After standard charged charge battery at 42mA 70mA for 28 days no fire or no explosion 5 10 2 Forced discharge The discharged battery is subjected to a reverse charge at 1400mA for 90 minutes no f...

Page 5: ...ry if above conditions cannot be met completely 7 2 Inside temperature of container must be below 20 if any client requires SOC above 35 the distance between battery master cartons not less than 10cm...

Page 6: ...charger or the equipment during used Be sure to use the recommended charging method for MOTOMA batteries read the battery charger s instruction manual carefully Do not use old and new batteries mixed...

Page 7: ...harging the battery unit The data sheet is for reference only and should not be used as a basis for product described guarantee or warranty Nominal voltage V 1 2 Capacity Typical 1400mAh Minimum 1400m...