MOTOMA NH-4-5SC1400P Technical Specification Download Page 4

                                                                  

MOTOMA POWER CO., LTD 

Http: //  www.motoma.com     

E-mail: [email protected] 

 

Manufacturer reserves the right to alter or amend the design, model and specification without prior notice. 

 

4 / 7 

 

 

Prior to the endurance  in cycles test, the battery shall  be discharged at 

140mA

 to 1.0V. The 

battery shall be capable of 500 minimum cycles under the conditions as follows. 

TABLE 3: Cycle Life Test 

Cycle 

Charge 

Rest 

Discharge 

0.1C for 16hours 

none 

0.25C×140mins 

2-48 

0.25C for 190minutes 

none 

0.25C×140mins 

49 

0.25C for 190minutes 

none 

0.25C to1.0V/ cell 

50 

0.1C for 16hours 

1-4hr(s) 

0.2C to 1.0V/cell 

Cycles 1 to 50 shall be repeated until the discharge time on any 50th cycle becomes less than 3 hours. At 

this stage, repeat 50th cycle, if the discharge time is less than 3 hours again the test is terminated. 

 

Note:

 If battery unit voltage drops below 1.0V, discharge shall be discontinued.

 

5.10 Safety 

5.10.1 Continuous low-rate charging 

 

After standard charged, charge battery  at 

42mA~70mA

 for 28 days, no fire or no  explosion. 

5.10.2 Forced discharge

 

The discharged battery is subjected to a reverse charge at 

1400mA

 for 90 minutes,  no fire or   

explode. 

5.11 Vibration 

The battery shall  be no fire, leakage or explode, when it is tested under the following 

conditions  after being standard charged. 

TABLE 4: Vibration Test Conditions 

Frequency

 

10~55Hz

 

Amplitude 

0.76mm 

Rate of frequency variety 

1 Hz/minute 

Duration 

90 minutes /axis (axis: X,Y,Z)  270 minutes in all 

5.12 Short Circuit 

After standard charged, short the battery until  the battery’s temperature returns to ambient 

temperature  (20±5

), no fire or no explosion.  (Cross section of the wire or connector  should  be 

more than  0.75mm

2

  

5.13 Impact Resistance 

      

After standard charged,  leave  the battery  for 24hrs,  then check  it before / after the following   

test:  Change of voltage: 

ΔV < 0.02V/cell; Change of internal Impedance:  ΔRi < 5 %/cell.

 

 

TABLE 5: Impact Resistance Test Conditions 

Standard Charged  Drop Height  Thickness of wooden board 

Direction 

Test Times 

0.1C for 16hrs 

50 cm

 

30mm 

Not specified 

 

5.14 Leakage 

Summary of Contents for NH-4-5SC1400P

Page 1: ...O DSE NH 4 5SC1400P10 V20A EDITION V20A DATE 2020 11 24 Prepared By Checked By Approved By QE1 QE A MOTOMAPOWER CO LTD Http www motoma com E mail info motoma com Manufacturer reserves the right to alt...

Page 2: ...for 2 4hours V 5mV 3 5 End voltage of discharge 1 0V 3 6 Operate temperature range relative humidity 45 85 Standard charge 0 45 Quick charge 10 40 Rapid charge 10 30 Discharge 10 50 3 7 Storage relat...

Page 3: ...BLE I Discharging performance at 20 Constant Discharge Current Rate Constant Discharge Current End Point Voltage Discharge Duration Available Capacity 3 0C 4 2A 0 8V 19min 95 5 0C 7 0A 0 8V 10 8min 90...

Page 4: ...ing After standard charged charge battery at 42mA 70mA for 28 days no fire or no explosion 5 10 2 Forced discharge The discharged battery is subjected to a reverse charge at 1400mA for 90 minutes no f...

Page 5: ...ry if above conditions cannot be met completely 7 2 Inside temperature of container must be below 20 if any client requires SOC above 35 the distance between battery master cartons not less than 10cm...

Page 6: ...charger or the equipment during used Be sure to use the recommended charging method for MOTOMA batteries read the battery charger s instruction manual carefully Do not use old and new batteries mixed...

Page 7: ...harging the battery unit The data sheet is for reference only and should not be used as a basis for product described guarantee or warranty Nominal voltage V 1 2 Capacity Typical 1400mAh Minimum 1400m...