motcom
®
BeCOMS
®
User Manual
Release
220601
Page 6.3
As soon as the Evaluator is powered up, it starts the initial self check procedure
and shows the READY status if all pre-set conditions are fulfilled. This self check
procedure is carried out in a certain cycle.
Regardless of the GREEN READY LED status of the Evaluator, if a working SRE
is connected to it, the Evaluator samples the signals from the SRE at a certain
sampling rate. After that, the Evaluator converts them into digital signals, analyzes,
evaluates and displays them on its LC-display.
These data including detected events are continuously made available through
the RS485 interface to the installed PC with
Data_Logger software for remote
monitoring and further processing. It is also possible to set up some Evaluator
parameters from the PC using standard Windows HyperTerminal application.
Depending on the configuration, the Data_Logger software can manage up to 6
BeCOMS
®
systems on a single computer. The measured values and events will
be monitored and displayed continuously on the computer, and stored in a distinct
directory on the hard disk for each connected BeCOMS
®
system.
6.3 Data Sampling
Summary of Contents for BeCOMS
Page 1: ...BeCOMS BCom Bearing Condition Monitoring UserManual Part No 1 900 00 00000 Release 220601...
Page 6: ...motcom BeCOMS User Manual Release 220601 Page vi...
Page 26: ...motcom BeCOMS User Manual Release 220601 Page 3 10...
Page 42: ...motcom BeCOMS User Manual Release 220601 Page 5 4...
Page 56: ...motcom BeCOMS User Manual Release 220601 Page 7 2...
Page 64: ...motcom BeCOMS User Manual Release 220601 Page 9 2...
Page 68: ...motcom BeCOMS User Manual Release 220601 Page 10 4...
Page 78: ...motcom BeCOMS User Manual Release 220601 Page 12 6 Fig 12 6 Dimension Slip Ring Encoder SRE...
Page 80: ...motcom BeCOMS User Manual Release 220601 Page 12 8 Fig 12 8 Dimensions Evaluator...
Page 81: ...motcom BeCOMS User Manual Release 220601 Page 12 9...