motcom
®
BeCOMS
®
User Manual
Release
220601
Page 4.12
Level 1
Level 2
Level 3
Descriptions
Read Relay
Switch the Ready relay ON and OFF
Alarm Relay
Switch the Alarm 1 relay ON and OFF.
Alm2/Pre Relay
Switch the Alarm 2 relay ON and OFF.
Testsignal A
Switch the test signal on channel A ON and OFF.
At the same time the values TS1 and TS2 are displayed (signals from the
first and the second thermovoltage measurement channels).
Testsignal B
Switch the test signal on channel B ON and OFF.
Hardware values
At the same time the values TS1 and TS2 are displayed (signals from the
first and the second thermovoltage measurement channels).
Table 3 Test Features Details