motcom
®
BeCOMS
®
User Manual
Release
220601
Page 4.10
Level 1
Level 2
Level 3
Descriptions
TS Test Time
Time interval between test pulses, possible values: 1 min to 10 min.
Test pulses help to check if the SRE sensor functions correct.
TS Test Len
The length of test pulse.
Possible values: 1 s to 15 s.
IS Impuls Offset
The offset between TDC of cylinder 1 and the synchronisation pulse at
the channel 0.
This value cannot be set at the Evaluator using the “Up” and “Down”
buttons. It is used during the impulse offset setup procedure as an
indicator.
To start the procedure, a PIN must be entered (refer to Table 2 on page
4.11)
PIN Impuls Offs
PIN for impulse offset setup, the procedure is the same as described in
Table 2 on page 4.11
TSeff ena for DC
Enable or disable (values 1 and 0 accordingly) calculating effective value of
thermosignal in percents of DC alarm level.
Values for TSeff
Number of points for calculating effective value of thermosignal in percents
of DC alarm level.
DC Alarm percent
Scale factor for DC alarm level, possible values: 80% to 199%.
AC Alarm percent
Scale factor for AC alarm level, possible values: 80% to 199%.
Summary of Contents for BeCOMS
Page 1: ...BeCOMS BCom Bearing Condition Monitoring UserManual Part No 1 900 00 00000 Release 220601...
Page 6: ...motcom BeCOMS User Manual Release 220601 Page vi...
Page 26: ...motcom BeCOMS User Manual Release 220601 Page 3 10...
Page 42: ...motcom BeCOMS User Manual Release 220601 Page 5 4...
Page 56: ...motcom BeCOMS User Manual Release 220601 Page 7 2...
Page 64: ...motcom BeCOMS User Manual Release 220601 Page 9 2...
Page 68: ...motcom BeCOMS User Manual Release 220601 Page 10 4...
Page 78: ...motcom BeCOMS User Manual Release 220601 Page 12 6 Fig 12 6 Dimension Slip Ring Encoder SRE...
Page 80: ...motcom BeCOMS User Manual Release 220601 Page 12 8 Fig 12 8 Dimensions Evaluator...
Page 81: ...motcom BeCOMS User Manual Release 220601 Page 12 9...