Part Number: 000016427 Rev 00 08/2020 93
REFRIGERATION COMPONENT DIAGNOSTIC CHART PKU0155
Operational Analysis
1
2
3
4
Ice Production
Published 24 hour ice production________________
Calculated (actual) 24 hour ice production_______________
NOTE: The ice machine is operating properly if the ice
fill pattern is normal and ice production is within 10% of
charted capacity.
Installation and Water
System
All installation and water related problems must be
corrected before proceeding with chart.
Ice Formation Pattern
Ice formation
is extremely
thin on top of
evaporator
-or-
No ice
formation
on the entire
evaporator
Ice formation
extremely thin
on top of the
evaporator
-or-
No ice
formation
on entire
evaporator
Ice formation
is normal
-or-
Ice formation
is extremely
thin on the
bottom of
evaporator
-or-
no ice
formation on
evaporator
Ice formation
is normal
-or-
No ice
formation
on entire
evaporator
Safety Limits
Refer to “Analyzing Safety
Limits” to eliminate all non-
refrigeration problems.
Stops on
safety limit:
1 or 2
Stops on
safety limit:
1
Stops on
safety limit:
1 or 2
Stops on
safety limit:
1
Freeze Cycle
Discharge Pressure
________ ______ _____
1 minute Middle End
into cycle
If discharge pressure is High or Low, refer to freeze cycle high
or low discharge pressure problem checklist to eliminate
problems and/or components not listed on this table before
proceeding.
Summary of Contents for PKM0335
Page 2: ......
Page 8: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 64: ...64 Part Number 000016427 Rev 00 08 2020 Troubleshooting THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 98: ...98 Part Number 000016427 Rev 00 08 2020 Troubleshooting THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 130: ...130 Part Number 000016427 Rev 00 08 2020 Specifications THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 131: ......
Page 132: ...Katom 305 Katom Drive Kodak Tennessee 37764 Part Number 000016427 Rev 00 08 2020 ...