22
Part Number: 000016427 Rev 00 08/2020
Requirements - Cleaning - Operation
5. Remove the Water Distribution Tube
A. Loosen the two thumbscrews, which secure the distribution tube.
B. Lift the right side of the distribution tube up off the locating pin.
C. Slide the distribution tube back.
D. Slide the distribution tube to the right and remove.
Dissemble the distribution tube - Twist both of the inner tube ends until the tabs line up
with the keyway and pull the inner tube ends outward.
6. Remove the Float Valve
• Turn the splash shield counterclockwise one or two turns and pull
the float valve forward and off the mounting bracket.
• Disconnect the water inlet tube from the float valve at the
compression fitting.
• Remove the cap and filter screen for cleaning.
7. Remove the Water Trough
• Apply downward pressure on the siphon tube and remove from the
bottom of the water trough.
• Remove the upper thumbscrew and while supporting the water
trough remove the two thumbscrews from beneath the water
trough.