Safety Limit 3
The harvest float switch hasn’t opened for 10 continuous seconds in the first 4 minutes
of the freeze cycle.
Possible Cause Checklist
Improper installation
• Refer to “Installation/Visual Inspection Checklist” on page 42
Water System
• Water dump valve
• Harvest float valve dirty or defective
• Low water pressure (20 psig min.)
• Dirty defective water filter (when used)
• Loss of water from sump area
• Dirty/defective water inlet valve
Electrical System
• Water inlet valve coil defective
• Harvest float valve defective