16
Part Number: 000016426 Rev 00 08/2020
GROUND FAULT CIRCUIT INTERRUPTER
Ground Fault Circuit Interrupter (GFCI/GFI) protection is a system that shuts down the
electric circuit (opens it) when it senses an unexpected loss of power, presumably to
ground. GFCI/GFI circuit protection is not recommended with our equipment. If code
requires the use of a GFCI/GFI, then you must follow the local code. The circuit must be
dedicated and sized properly, and there must be a panel GFCI/GFI breaker. We do not
recommend GFCI/GFI outlets as they are known for more intermittent nuisance trips than
panel breakers.
MINIMUM POWER CORD SPECIFICATIONS
Maximum Breaker Size
Minimum Wire
Size
Maximum Length of Power
Cord
15 amp
14 gauge
6 feet (1.83 m)
20 amp
12 gauge
6 feet (1.83 m)
If a power cord is used, the wire size to the receptacle is dependent upon location,
materials used, length of run, etc., so it must be determined by a qualified electrician.
Local, state or national requirements will supersede our minimum requirements.
Maximum Breaker Size & Minimum Circuit Amperage Chart
Important
Due to continuous improvements, this information is for reference only. Please refer
to the ice machine serial number tag to verify electrical data. Serial tag information
overrides information listed on this page.
Ice Machine
Voltage/Phase/
Cycle
Maximum Fuse
or
Circuit Breaker
Minimum Circuit
Amps
Total Amps
PKU0155
115/1/60
15
N/A
7.4
PKM0335
115/1/60
15
9.44
N/A
PKM0425
115/1/60
20
11.3
N/A
PKM0535
115/1/60
20
12.7
N/A