![Moss LED PixlArt 416 User Manual Download Page 12](http://html1.mh-extra.com/html/moss-led/pixlart-416/pixlart-416_user-manual_1837238012.webp)
11
PixlArt416 V1.0 User Manual V1.1
© 2018 Moss LED Inc.
This output acts as an individual DMX512 universe output, effectively providing the user with an
E1.31 to DMX512 bridge (
in addition
to the normal pixel outputs). These do
not
convert Art-net
data to DMX, only sACN (E1.31).
The DMX outputs are
not
electrically isolated and are not recommended for commercial/industrial
use.
All these connectors and jumper links are located on the far
left
-hand edge of the board as shown in
figure 6.
Figure 6
5.4
–
Hardware Test Pattern
The controller features a built-in test pattern to assist in troubleshooting during an installation. To
put the controller into this mode,
press and hold the ‘Factory IP’
button for 3 seconds (
after
the
controller is already running.) The controller will then enter the test pattern mode and will display
red, green, blue and white sequentially in a repeating pattern on all pixels on each of the 4 outputs.
Pressing the button while in this mode will then cycle through each of the four colors successively
(on all outputs simultaneously) before returning to the current pattern again.
To exit the test mode press and hold the
‘Factory IP’
button down again for 3 seconds and then
release.
The hardware test requires that the pixel driver chip type and number of pixels per output are set
correctly in the configuration. In this way you can test if that part of your configuration is correct and
isolate other possible problems with the incoming Ethernet data side.