19/05/05 76440-GB
TECHNICAL DATA
TS 400 PS
TS 500 PS
M
1.5
REV.3-10/13
I
GB
F
Technical data
TS 400 PS
TS 500 PS
A.C. GENERATOR
Three-phase generation
16 kVA / 400 V / 23.1 A
Single-phase generation
12 kVA / 230 V / 52.2 A
Single-phase generation
6 kVA / 110 V / 54.4 A
Single-phase generation
5 kVA / 48 V / 104 A
-
Frequency
50 Hz
60 Hz
ALTERNATOR
self-excited, self-regulated, brushless
Type
three-phase, asynchronous
Insulating class
H
ENGINE
Mark / Model
PERKINS / 404 D-22G
Type / Cooling system
Diesel 4-stroke / Liquid
Cylinders / Displacement
4 / 2216 cm
3
Net output
20.3 kW (27.6 HP)
22.6 kW (30.7 HP)
Speed
1500 rpm
1800 rpm
Fuel consumption (welder 60%)
3.8 l/h
4.2 l/h
Cooling system capacity
7 l
Engine oil capacity
8.5 l
Starter
Electric
GENERAL SPECIFICATIONS
Battery
12V - 100Ah
Tank capacity
60 l
Running time (welder 60%)
16 h
Protection
IP 23
Dimensions / max. Lxwxh (mm) *
1720x980x1110
Weight
780 Kg@
Measured acoustic power LwA (pressure LpA)
91 dB(A) (66 dB(A) @ 7m)
Guaranteed acoustic power LwA (pressure LpA)
92 dB(A) (67 dB(A) @ 7m)
Acoustic power LwA (pressure LpA)
94 dB(A) (69 dB(A) @ 7m)
* Dimensions and weight are inclusive of all parts without wheels and towbar
POWER
Declared power according to
ISO 3046-1 (temperature 25°C, 30% relative humidity, altitude 100 m above sea level).
It’s admitted overload of 10% each hour every 12 h.
In an
approximative
way one reduces: of 1% every 100 m altitude and of 2.5% for every 5°C above 25°C.
ACOUSTIC POWER LEVEL
ATTENTION
:
The concrete risk due to the machine depends on the conditions in which it is used. Therefore, it is up to the end-
user and under his direct responsibility to make a correct evaluation of the same risk and to adopt specific precautions (for
instance, adopting a I.P.D. -Individual Protection Device)
Acoustic Noise Level
(L
WA
)
- Measure Unit dB(A)
:
it stands for acoustic noise released in a certain delay of time. This is not
submitted to the distance of measurement.
Acoustic Pressure (Lp)
- Measure Unit dB(A)
:
it measures the pressure originated by sound waves emission. Its value changes
in proportion to the distance of measurement.
The here below table shows examples of acoustic pressure (Lp) at different distances from a machine with Acoustic Noise Level
(
L
WA
)
of 95 dB(A)
Lp a 1 meter = 95 dB(A) - 8 dB(A) = 87 dB(A)
Lp a 7 meters = 95 dB(A) - 25 dB(A) = 70 dB(A)
Lp a 4 meters = 95 dB(A) - 20 dB(A) = 75 dB(A)
Lp a 10 meters = 95 dB(A) - 28 dB(A) = 67 dB(A)
PLEASE NOTE
:
the symbol when with acoustic noise values, indicates that the device respects noise emission limits
according to 2000/14/CE directive.
2000 / 14 / CE
2000 / 14 / CE