The
TS 300
engine driven welder ia a unit which ensures the function as:
a) a current source for arc welding
b) a current source for the auxiliary power generation
It is meant for industrial and professional use, powered by an endothermic engine; it is composed of
various main parts such as: engine, alternator, electric and electronic controls, the fairing or a protective structure.
The assembling is made on a steel structure, on which are provided elastic support which must damp the vibrations and also
eliminate sounds which would produce noise.
14/04/14
37304-GB
Technical data
TS 300 KS - KSX
M
1.5
REV.0-04/14
Technical data
TS 300 KS
TS 300 KSX
ALTERNATOR
self-excited, self-regulated, brushless
Type
Three-phase, asynchronous
Insulating class
H
A.C. GENERATORA.
Three-phase generation
10 kVA / 400 V / 14.4 A
Single-phase generation
5 kVA / 230 V / 21.7 A
Single-phase generation
2.5 kVA / 110 V / 22.7 4
Single-phase generation
5 kVA / 48 V / 104 A
Frequency
50 Hz
ENGINE
Mark / Model
KOHLER KD 477/2
Type / Cooling system
Diesel 4-Stroke / Air
Cylinders / Displacement
2 / 954 cm
3
Net output
14.9 kW (20.3 HP)
Speed
3000 rpm
Fuel consumption (welder 60%)
2.5 l/h
Engine oil capacity
3 l
Starter
Electric
GENERAL SPECIFICATIONS
Battery
12V - 45Ah
Tank capacity
23 l
Running time (welder 60%)
9.2 h
Protection
IP 23
Dimensions / max. (Lxlxh in mm)
1320x790x750
Dimensions with CTM
1630x920x930
Dimensions with CTL
2050x980x990
Weight
350 Kg
370 Kg
Weight with CTM
370 Kg
390 Kg
Weight with CTL
410 Kg
440 Kg
Acoustic power LwA (pression LpA)
99 dB(A) (74 dB(A) @ 7m)
-
Measured acoustic power LwA (pression LpA)
-
96 dB(A)(71 dB(A) @ 7m)
Guaranteed acoustic power LwA (pression LpA)
-
97 dB(A)(72 dB(A) @ 7m)
POWER
Declared power according to
ISO 3046-1 (temperature 25°C, 30% relative hummidity, altitude 100 m above sea level).
It’s admitted overload of 10% each hour every 12 h.
In an
approximative
way one reduces: of 1% every 100 m altitude and of 2.5% for every 5°C above 25°C.
ACOUSTIC POWER LEVEL
ATTENTION:
The concrete risk due to the machine depends on the conditions in which it is used. Therefore, it is up to the end-
user and under his direct responsibility to make a correct evaluation of the same risk and to adopt specific precautions (for
instance, adopting a I.P.D. -Individual Protection Device)
Acoustic Noise Level
(L
WA
)
- Measure Unit dB(A):
it stands for acoustic noise released in a certain delay of time. This is not
submitted to the distance of measurement.
Acoustic Pressure (Lp)
- Measure Unit dB(A):
it measures the pressure originated by sound waves emission. Its value changes
in proportion to the distance of measurement.
The here below table shows examples of acoustic pressure (Lp) at different distances from a machine with Acoustic Noise Level
(
L
WA
)
of 95 dB(A)
Lp a 1 meter = 95 dB(A) - 8 dB(A) = 87 dB(A)
Lp a 7 meters = 95 dB(A) - 25 dB(A) = 70 dB(A)
Lp a 4 meters = 95 dB(A) - 20 dB(A) = 75 dB(A)
Lp a 10 meters = 95 dB(A) - 28 dB(A) = 67 dB(A)
PLEASE NOTE:
the symbol when with acoustic noise values, indicates that the device respects noise emission limits
according to 2000/14/CE directive.
2000 / 14 / CE
2000 / 14 / CE