background image

10/10/02 M1-1_EN

ENGLISH

ENGLISH

REV
.0-10/02

M

1.1

INTRODUCTION

Dear Customer,

We wish to thank you for having bought a high quality set.

Our sections for Technical Service and Spare Parts will work at 

best to help you if it were necessary.

To this purpose we advise you, for all control and overhaul 

operations, to turn to the nearest authorized Service Centre, 

where you will obtain a prompt and specialized intervention.

+

 In case you do not profit on these Services and some arts 

are replaced, please ask and be sure that are used exclusi-

vely original parts; this to guarantee that the performances 

and the initial safety prescribed by the norms in force are 

re-established.

+

The use 

of

 non original spare parts will cancel immediately

 

any guarantee and Technical Service obligation.

NOTES ABOUT  THE MANUAL

Before actioning the machine please read this manual atten-

tively. Follow the instructions contained in it, in this way you will 

avoid inconveniences due to negligence, mistakes or incorrect 

maintenance. The manual is for qualified personnel, who knows 

the rules: about safety and health, installation and use of sets 

movable as well as fixed.

You must remember that, in case you have difficulties for use 

or installation or others, our Technical Service is always at your 

disposal for explanations or interventions.

The manual for Use Maintenance and Spare Parts is an inte-

grant part of the product. It must be kept with care during all 

the life of the product.

In case the machine and/or the set should be yielded to another 

user, this manual must also given to him.

Do not damage it, do not take parts away, do not tear pages and 

keep it in places protected from dampness and heat.

You must take into account that some figures contained in it 

want only to identify the described parts and therefore might 

not correspond to the machine in your possession.

INFORMATION OF GENERAL TYPE

In the envelope given together with the machine and/or set you 

will find: the manual for Use Maintenance and Spare Parts, 

the manual for use of the engine and the tools (if included in 

the equipment), the guarantee (in the countries where it is 

prescribed by law).

+

 

NOTICE:

 the manufacturer, who keeps the faculty, apart 

the essential characteristics of the model here described 

and illustrated, to bring betterments and modifications to 

parts and accessories, without putting this manual uptodate 

immediately.

The Manufacturer shall not be liable for ANY USE OF THE PRO-

DUCT OTHER THAN THAT PRECISELY SPECIFIED IN THIS 

MANUAL and is thus not liable for any risks which may occur as 

a result of IMPROPER USE. The Company does not assume 

any liability for any damage to persons, animals or property.

Our products are made in conformity with the safety norms in 

force, for which it is advisable to use all these devices or informa-

tion so that the use does not bring damage to persons or things.

While working it is advisable to keep to the personal safety 

norms in force in the countries to which the product is destined 

(clothing, work tools, etc.).

Do not modify for any motive parts of the machine (fastenings, 

holes, electric or mechanical devices, others..) if not duly au-

thorized in writing: the responsibility coming from any potential 

intervention will fall on the executioner as in fact he becomes 

maker of the machine.

Summary of Contents for TF II9 Y

Page 1: ...n Lichtmasten Torresdeilumina o VerlichtingTowers 8B9729003 LIGHT ENERGY TF II9 Y STAGE V Codice Code Code Codigo Kodezahl C digo Code Edizione Edition dition Edici n Ausgabe Edi o Editie 04 2019 USE...

Page 2: ......

Page 3: ...12 M4 2 TRANSPORT AND HANDLING PAG 13 3 INSTALLATION AND USE M2 7 INSTALLATION PAG 15 M20 SET UP FOR OPERATION DIESEL ENGINE PAG 16 EARTHING PAG 18 M21 STARTING AND STOPPING EP6 PAG 19 M23 1 Start up...

Page 4: ...must also given to him Do not damage it do not take parts away do not tear pages and keep it in places protected from dampness and heat You must take into account that some figures contained in it wa...

Page 5: ...shown the noise level value the symbol used is the following The indication is shown in a clear readable and indeleble way on a sticker 1 Name or brand supplier 2 Light tower model 3 Serial number re...

Page 6: ...damage can happen to persons or things HIGH VOLTAGE Attention High Voltage There can be parts in voltage dangerous to touch The non observance of the advice implies life danger FIRE Danger of flame or...

Page 7: ...doctor Suction of liquids from lungs If you suppose that vomit has entered the lungs as in case of spontaneous vomit take the subject to the hospital with the utmost urgency Inhalation In case of expo...

Page 8: ...trailers or site tows Never drag the machine without trailer or site tow Check for a correct assembly of the machine to the towing device Always make sure that the hook of the vehicle is suitable for...

Page 9: ...N AND USE Make sure the area above the lighting tower is free from overhead cables or other obstacles Before raising the mast extract the outriggers located at the sides of the machine Acting on the o...

Page 10: ...er floodlights and various types of lamps LED metal halide exc A silent generator driven by a water cooled low fuel consumption engine A command and control panel for the overall management and protec...

Page 11: ...t machine is necessary to record some data Please write the requested data inside the squares to side 1 Model of machine 2 Serial number of the machine 3 Serial number of the engine 4 Name of the deal...

Page 12: ...andling or taking away of parts contained inside the packing or in the set In case you find damages rough handling or absence of parts envelopes manuals etc we advise you to inform immediately our Tec...

Page 13: ...Climb the ladder being suppor ted by a second operator and wear special non slip shoes MOVING THE GENERATING SET VIA FORKLIFT When lifting with a forklift it is necessary to Insert the forks of the f...

Page 14: ...force in the place of use shall be respected SITE TOW CTL this trailer is made by the manufacturer it can not be towed on public roads Therefore it can only be used on private roads and no through tra...

Page 15: ...07 10 13 8B972_EN M 2 7 INSTALLAZIONE INSTALLATION INSTALLATION INSTALACI N LUFTZIRKULATION INSTALA O INSTALLATIE REV 0 10 13...

Page 16: ...e battery by means of the indicator placed in the upper part Green colour battery OK Black colour battery to be recharged White colour battery to be replaced DO NOT OPEN THE BATTERY FUEL Refill the ta...

Page 17: ...would originate gelatinous substances capable of obstructing the cooling system ATTENTION Do not remove the radiator tap with the motor in operation or still hot as the liquid coolant may spurt out a...

Page 18: ...t by means of the GFI Connect the generating set to an earthing system via a cable certain efficiency using the ground terminal 12 on the machine Earthing WITH GROUND FAULT INTERRUPTER The grounding c...

Page 19: ...6 blocks the starting and on the display the word fail appears Turning the key on OFF the EP6 is reset and a new starting cycle can be fixed Stop it is COMPULSORY to disconnect the load first then to...

Page 20: ...ondition PRELIMINARY CHECKS Check the engine oil level hydraulic oil and radiator fluid Check the fuel level POSITIONING OF THE OUTRIGGERS AND LEVELLING OF THE TOWER Block the wheels using the hand br...

Page 21: ...case of emergency due to engine failure or due to failure of the hydraulic or the electrical system use the bypass tap of the solenoid valve to lower the mast When the mast is completely down close th...

Page 22: ...lampe Schalter ON OFF Lampe N9 Pulsante comando salita discesa palo UP DOWN button mast Bouton commande mont e de scendue poteau Taste Mast Steuerung ansteigen sinken R3 Avvisatore acustico Siren Aver...

Page 23: ...A P T the display will show the message tESt 2 2 MANUAL OPERATING MODE To start the engine follow the instructions A Turn ON the KEY SWITCH the EP6 illuminates the LEDs and Display B If the display sh...

Page 24: ...d ON The LEDs and DISPLAY light up for about 1 second 6 0 PARAMETERS AND SETTINGS The unit is programmed by the supplier of the Generating Set Contact the Generator manufacturer in order to have the p...

Page 25: ...ed by about 6 seconds The EP6 shuts down the engine and the display will show the Lo H message P 9 Generator Over Frequency 55 45 Hz to inh inh disables the over frequency This protection is delayed b...

Page 26: ...nge 0 99 secs By Pass Delay to ignore the Oil Pressure input 3 during the engine starting cycle This input requires normally closed contact P 26 Automatic Periodic Test Cycle inh Range inh 1 99 days T...

Page 27: ...the periodic tests To avoid error accumulation and in case your unit is programmed to allowAutomatic Periodic Test we recommend the following procedures disconnect the power supply of the EP6 consult...

Page 28: ...ting Manual DIESEL ENGINE The motor does not start up or starts up and then stops immediately 1 Lack of fuel in tank or fuel tap closed 2 Fuel filter clogged 3 Air leaks in fuel system 4 Battery not a...

Page 29: ...eed due to overload 2 Load with cos less than the nominal one 3 Alternator fault 4 Faulty AVR 1 Check the load connected and decrease 2 Reduce or rephase load 3 Check winding diodes etc on alternator...

Page 30: ...ECALS AND LABELS All warning and decals should be checked once a year and replaced if missing or unreadable STRENUOUS OPERATING CONDITIONS Under extreme operating conditions frequent stops and starts...

Page 31: ...th the requirements given in section SAFETY PRECAUTIONS DURING MAINTENANCE HYDRAULIC POWER PACK A Electric Motor B Bypass tap for manual lowering of the mast C Hydraulic fluid tank Check the level and...

Page 32: ...iler 2 x 185 65 R 14 Fast Tow Highway Trailer Homologated 2 x 195 50 R 13 ENGINE Watercooling MODEL YANMAR 3TNV80 STAGE V NET POWER ST BY PRP 9 2 kW 8 3 kW 1500 rpm CYLINDERS DISPLACEMENT 3 1267 cm FU...

Page 33: ...kg M H 1040 kg Led TYRES Site Tow Trailer 2 x 185 65 R 14 Fast Tow Highway Trailer Homologated 2 x 195 50 R 13 ENGINE Watercooling MODEL KOLHER KDW 1003 STAGE V NET POWER ST BY PRP 8 kW 7 7 kW 1500 r...

Page 34: ...aximum power available for use with constant load for an unlimited number of hours year A 10 overload is permitted one out of every 12 hours On average it reduces by 1 every 1000 m above sea level and...

Page 35: ...07 10 13 8B972_EN M 2 7 1 DIMENSIONI DIMENSIONS DIMENSIONS DIMENSIONES ABMESSUNGEN DIMENS ES AFMETINGEN REV 1 12 15...

Page 36: ...07 10 13 8B972_EN M 2 7 2 DIMENSIONI DIMENSIONS DIMENSIONS DIMENSIONES ABMESSUNGEN DIMENS ES AFMETINGEN REV 1 12 15...

Page 37: ...07 10 13 8B972_EN M 2 7 3 DIMENSIONI DIMENSIONS DIMENSIONS DIMENSIONES ABMESSUNGEN DIMENS ES AFMETINGEN REV 1 12 15...

Page 38: ...ridge Y4 PCB control unit polarity inverter A5 Base current switch B5 Auxiliary push button ON OFF C5 Accelerator electronic control D5 Actuator E5 Pick up F5 Warning light high temperature G5 Commuta...

Page 39: ...07 10 13 8B972_IT M 61 SCHEMA ELETTRICO ELECTRIC DIAGRAM SCHEMAS ELECTRIQUES ESQUEMA EL CTRICO STROM LAUFPLAN Esquema el ctrico ELECTRISCH GEDEELTE yanmar TF II 9 Y REV 0 12 15...

Page 40: ...ro black 2 S1 M R1 7 3 4 6 8 6 3 4 8 2 White Red G1 V EP6 U7 RPM 22 1 16 16 11 H1 L1 5 K1 30 87 87a start 20 10 10 1 7 14 15 13 13 5 9 6 3 4 RPM GND 30 V 1 7 1 5 1 2 L5 1 2 K1 86 85 N3 start K2 86 85...

Page 41: ...07 10 13 8B972_IT M 61 SCHEMA ELETTRICO ELECTRIC DIAGRAM SCHEMAS ELECTRIQUES ESQUEMA EL CTRICO STROM LAUFPLAN Esquema el ctrico ELECTRISCH GEDEELTE TF II 9 Y J 4x1000 REV 0 12 15...

Page 42: ...M 61 SCHEMA ELETTRICO ELECTRIC DIAGRAM SCHEMAS ELECTRIQUES ESQUEMA EL CTRICO STROM LAUFPLAN Esquema el ctrico ELECTRISCH GEDEELTE TF II 9 Y J 4x1000 TF NI 9 J 4x1000 TF NM 5 5 J 4x400 TF IM 5 5 Y J 4...

Page 43: ...07 10 13 8B972_IT M 61 SCHEMA ELETTRICO ELECTRIC DIAGRAM SCHEMAS ELECTRIQUES ESQUEMA EL CTRICO STROM LAUFPLAN Esquema el ctrico ELECTRISCH GEDEELTE TF II 9 Y L 4x280 REV 0 12 15...

Page 44: ...07 10 13 8B972_IT M 61 SCHEMA ELETTRICO ELECTRIC DIAGRAM SCHEMAS ELECTRIQUES ESQUEMA EL CTRICO STROM LAUFPLAN Esquema el ctrico ELECTRISCH GEDEELTE TF II 9 Y L 4x280 REV 0 12 15...

Page 45: ...11 01 01 Note NOTE...

Page 46: ...11 01 01 Note NOTE...

Page 47: ......

Page 48: ...MOSA div della BCS S p A Viale Europa 59 20090 Cusago Milano Italy Tel 39 0290352 1 Fax 39 0290390466 www mosa it...