WARNING
It is absolutely forbidden to connect the
unit to the public mains and/or another
electrical power source.
Areas for which access by non-authorized
personnel is
forbidden
are:
- the control panel (at the front) - the endo-
thermic motor discharge.
M
37
MAGIC WELD 200
AUXILIARY GENERATION IN AC 230V/50Hz
The auxiliary output is drawn by means of a 3 pole
socket, the two poles are live, phase and neutral,
plus the earth for the machine.
The single phase generation of the machine was
designed to supply small power tools (grinders, drills
etc.) to assist the welding operations with a quick,
safe connection without the need to connect to
earth. In addition, supplying only one tool at a time,
the protection against indirect contact is assured by
“electrical separation”.
Therefore, the machine MUST NOT be intentionally
connected to earth, attaching cables must be of 3
wires and the electrical equipment on which it being
used must have an extension length limited to 100-
200 metres. This limitation of circuit extension length
is fundamental for safety.
The cables must be SUITED to the environment
in which they are to be used. Bear in mind that at
temperatures below 5°C PVC cables become rigid
and the PVC insulation tends to split at the first
crease.
Using double insulated equipment is advisable,
this is identifiable by the symbol and for having
no earth facility.
If the machine is designed to supply circuits which
are particularly complex or in an area with potential
electrical risk, it is required to interpose a complete
electrical distribution panel, equipped with all
electrical protections required, between the plug
and loads.
For example: you can use a distribution system
TN-S. In this case one of the phases, used as
a neutral must be grounded; a bipolar 30mA
differential switch (GFI) must be mounted inside
the electrical box, before the sockets to which
loads are connected; the terminal in the frontal
panel of the generating set near the socket is to be
used as earth connection, wiring it to the ground of
the electrical plant with which the machine is going
to work.
WARNING
: bound the neutral to frame BEFORE
the GFI.